Built for high-volume operations that demand consistent temperature control and reliable storage capacity, this walk-in cooler delivers enduring performance without compromise. Designed for indoor installations with remote refrigeration, the unit supports medium temperature storage at +35F while minimizing footprint and maintenance time. Operators gain a robust storage environment that fits busy kitchens, institutions, and hospitality back-of-house workflows.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the cooler before cleaning. Remove food and shelving; wash shelves with warm, soapy water. Clean interior panels with mild detergent on a soft cloth; avoid abrasives. Vacuum condenser coils monthly and degrease vents. Check door seals for cracks and replace when worn. Sanitize food-contact surfaces with an approved sanitizer. Dry all surfaces completely before reconnecting power. Regular cleaning prevents contamination, cuts energy use, and reduces repair risk.#@@#Additional Info#@#Kolpak's KFX7-1006-CR indoor cooler is 90" H x 116" W x 70" D, uses R-404A refrigerant, operates at 208/230 volts for +35°F, has a floorless design, 4" vinyl/foam screeds, and includes a 2" dial thermometer.#@@#General Info#@#Description #@#
Built for high-volume operations that demand consistent temperature control and reliable storage capacity, this walk-in cooler delivers enduring performance without compromise. Designed for indoor installations with remote refrigeration, the unit supports medium temperature storage at +35F while minimizing footprint and maintenance time. Operators gain a robust storage environment that fits busy kitchens, institutions, and hospitality back-of-house workflows.
#@@# Galvalume Finish#@#
Galvalume construction on interior and exterior panels provides corrosion resistance and a clean appearance. Maintenance teams access smooth surfaces that withstand frequent cleaning while sustaining structural integrity in humid environments.
#@@# Floorless Design#@#
Floorless configuration simplifies integration with existing floor plans and drains, eliminating field floor work and reducing installation time. Technicians install the cooler over existing flooring to preserve site finishes and accelerate project schedules.
#@@# Remote Refrigeration#@#
Remote refrigeration with pre-charged capability separates the condensing unit from the box, reducing heat and noise in service areas. Engineers position the remote unit outdoors to optimize cooling efficiency and extend compressor life while using R-404A refrigerant for established medium temperature performance.
#@@# Insulation Screeds#@#
Four-inch vinyl and foam screeds seal the base perimeter to maintain temperature integrity and limit air infiltration. Facility managers observe stable interior conditions that reduce compressor cycles and energy waste.
#@@# Thermometer Control#@#
A 2-inch dial thermometer mounts for straightforward temperature monitoring and verification during routine checks. Staff perform quick visual inspections to confirm +35F setpoints and document compliance with storage protocols.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect gaskets weekly and replace any sections showing cracks or compression to maintain consistent seals. Clean interior and exterior galvalume panels with a pH-neutral detergent and soft cloth; avoid abrasive pads. Vacuum condenser coils monthly and confirm remote refrigeration lines show no oil or frost buildup. Calibrate the 2" dial thermometer quarterly and log temperatures at least twice daily. Tighten fasteners and check screeds for voids during preventive maintenance.