Engineered for continuous cold storage in demanding food service environments, this indoor walk-in freezer combines robust construction with efficient remote refrigeration to protect inventory and maintain consistent low temperatures. Designed for installation flexibility, the unit accepts a pre-charged remote condensing system and operates on 208/230 volts with a 2-1/2 HP compressor to support sustained low-temperature performance. Contractors and facilities managers receive a modular solution sized at 90 inches high by 116 inches wide by 93 inches deep, balancing footprint and capacity for commercial kitchens, cafeterias, and institutional pantries.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and remove contents. Clean interior panels, ceiling, and door gasket with mild detergent and warm water; scrub the floor with a soft brush and non-abrasive cleaner. Rinse and dry surfaces to prevent corrosion. Clean condenser coils and fan blades quarterly to maintain efficiency. Remove grease from vents and oven areas to reduce fire risk. Inspect seals and replace worn gaskets. Regular cleaning removes bacteria, prevents breakdowns, and helps pass CSA and health inspections.#@@#Additional Info#@#Kolpak KF7-1008-FR indoor walk-in freezer is 90" H x 116" W x 93" D with a 2-1/2 HP, 208/230 volts remote refrigeration system using R-448A.#@@#General Info#@#Description #@#
Engineered for continuous cold storage in demanding food service environments, this indoor walk-in freezer combines robust construction with efficient remote refrigeration to protect inventory and maintain consistent low temperatures. Designed for installation flexibility, the unit accepts a pre-charged remote condensing system and operates on 208/230 volts with a 2-1/2 HP compressor to support sustained low-temperature performance. Contractors and facilities managers receive a modular solution sized at 90 inches high by 116 inches wide by 93 inches deep, balancing footprint and capacity for commercial kitchens, cafeterias, and institutional pantries.
#@@# Interior Construction#@#
The interior utilizes 26 gauge embossed galvalume panels that resist corrosion while providing a smooth, hygienic surface. Technicians can clean surfaces easily without abrasive treatments, and the finish supports long-term durability in high-moisture cold rooms.
#@@# Floor System#@#
The freezer includes a .10 smooth aluminum Era floor that offers an even load surface and corrosion resistance. Operations staff benefit from a continuous floor that simplifies pallet movement and reduces wear under heavy traffic.
#@@# Thermal Performance#@#
The system targets low-temperature operation to minus 10°F using R-448A refrigerant and a remote refrigeration architecture. Facility engineers gain improved efficiency and service access by locating the condensing unit remotely while maintaining consistent internal temperatures.
#@@# Controls and Monitoring#@#
The unit ships with a 2-inch dial thermometer that provides visible temperature feedback at a glance. Supervisors can verify set points quickly during routine checks without needing to access remote monitoring systems.
#@@# Compliance and Safety#@#
The walk-in carries NSF, cUL, and UL certifications that align with food safety and electrical standards for commercial installations.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect door gaskets weekly and replace seals showing cracks or deformation to preserve temperature integrity. Clean condenser coils monthly with a soft brush and low-pressure air to maintain heat exchange efficiency. Sanitize interior panels and the Era floor with a neutral pH cleaner; rinse to remove residues. Verify thermometer calibration quarterly and record temperatures. Lubricate hinges and check drain lines for blockages to prevent ice buildup and ensure reliable operation.