For high-volume kitchens that require organized cold storage and rapid access, this three-section sandwich unit provides precise temperature control, configurable drawer capacity, and durable construction suited for continuous service. Designed for culinary operations, the counter-height unit combines a stainless steel worktop and cutting board with a drawer-based refrigeration system that optimizes ingredient staging and reduces service time. The rear-mounted self-contained refrigeration utilizes R290 hydrocarbon refrigerant and a 1/4 HP compressor to maintain stable temperatures while adhering to efficiency and safety standards.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug unit. Remove pans and cutting board. Wipe stainless steel top, front and ends with mild detergent and a soft cloth. Clean aluminum interior and drawers with warm, soapy water; rinse and dry. Vacuum condenser coils behind unit monthly to maintain efficiency. Inspect door seals and drawer gaskets; replace if cracked. Use non-abrasive cleaners. Allow components to dry fully before reconnecting power to prevent electrical faults.#@@#Additional Info#@#Continental Refrigerator SW72N18C-D is a 72" three-section sandwich unit with 20.6 cu ft capacity, stainless steel exterior, six drawers, 18 pan capacity, electronic digital control, R-290 refrigeration, 115v, NSF and cETLus certified.#@@#General Info#@#Description #@#
For high-volume kitchens that require organized cold storage and rapid access, this three-section sandwich unit provides precise temperature control, configurable drawer capacity, and durable construction suited for continuous service. Designed for culinary operations, the counter-height unit combines a stainless steel worktop and cutting board with a drawer-based refrigeration system that optimizes ingredient staging and reduces service time. The rear-mounted self-contained refrigeration utilizes R290 hydrocarbon refrigerant and a 1/4 HP compressor to maintain stable temperatures while adhering to efficiency and safety standards.
#@@# Construction Materials#@#
Stainless steel top, front, and end panels offer a hygienic work surface and resist corrosion in high-use back-of-house environments. Aluminum interior and back reduce weight while preserving thermal performance, supporting daily cleaning protocols without surface degradation.
#@@# Capacity Management#@#
The unit accommodates eighteen 1/6 size pans at 4" depth across three sections and six drawers, yielding 20.6 cubic feet of refrigerated volume for ingredient organization. Each drawer accepts one 12 x 18 x 6 pan or a combination of pans per drawer, enabling flexible portioning and simplified mise en place.
#@@# Refrigeration System#@#
A rear-mounted self-contained refrigeration system with an automatic hot gas condensate evaporator eliminates the need for external drainage and reduces maintenance interventions. The system operates on R290 refrigerant with a 1/4 HP compressor, delivering reliable cooling while meeting modern refrigerant efficiency profiles.
#@@# Controls and Monitoring#@#
Electronic controls with a digital display provide straightforward setpoint adjustment and real-time temperature readout for critical cold-chain management. The integrated hi-low alarm notifies staff of excursions, enabling immediate corrective action to preserve ingredient integrity.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Maintain the Continental Refrigerator SW72N18C-D by cleaning condenser coils monthly to preserve 20.6 cu ft cooling efficiency. Sanitize stainless steel top, front and end panels with pH-neutral detergent; rinse and dry to prevent corrosion. Remove drawers and wash pans with warm, soapy water; inspect gasket seals and replace if cracked. Verify electronic control accuracy and test hi-low alarm regularly. Defrost drain line quarterly and confirm R290 system shows no leaks.