Skip to main content

Continental Refrigerator D2RENSSSGD 57" W Two-Section Glass Door Reach-In Designer Line Wide Refrigerator

Continental Refrigerator

Was: $23,344.00
Now: $20,657.74
(No reviews yet) Write a Review
SKU:
DL2RE-SS-SGD
Weight:
665.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
D2RENSSSGD__1074
Compressor HP:
1/2
Door Style:
Sliding Half
Door Type:
Glass
Energy Efficiency:
ENERGY STAR®
Exterior Finish:
Stainless Steel
Interior Finish:
Stainless Steel
Nema Plug Type:
NEMA 5-15P
Number of Sections:
2
Refrigerant Type:
R-290
Refrigeration:
Self-contained
email_price:
no
Tags:
Refrigerator, Reach-In
Label Option type:
rectangles
Net Price:
18908.69
msrp_price:
no
Ship From:
19020
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Reach-In Refrigerators and Freezers>>Reach-In Refrigerators
Allow to show add to cart:
Login or Add to Cart to See Price
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 523-7138
Freight Class:
150
add_to_cart:
no
MAP Price:
23344
Manufacturer:
Continental Refrigerator
login_price:
yes
Product ID:
006dfd2e-c00d-dd11-a23a-00304834a8c9
List Price:
54606
Taxonomy Weight:
665
Filter_Sections:
2
Filter_Door Type:
Glass
Filter_Refrigerant Type:
R-290
Trigger BC Integration:
Y-6/19/2026_1:05PM
Primary Image:
DL2RE-SS-SGD.png
Sale Price:
20657.74383
Filter_Manufacturer:
Continental Refrigerator
Filter Construction:
All Stainless Steel
Filter_Construction:
All Stainless Steel
specsheet:
Continental Refrigerator_DL2RE-SS-SGD.pdf
warranty:
Continental Refrigerator_DL2RE-SS-SGD_1.pdf
Filter_Number of Doors:
2 Doors
Number of Doors:
2
Voltage:
115v
Filter_Voltage:
115 Volts
NSF Certified:
Yes
cETLus Certified:
Yes
manual:
Continental Refrigerator_DL2RE-SS-SGD_2.pdf
Capacity:
52 Cu. Ft.
Filter_Capacity:
47 - 69 Cubic Feet
Filter_Hinge Location:
Left/Right
Filter_NSF Listed:
Yes
Filter_Compressor Location:
Top Mounted
Keyfeatures5:
Digital control with hi-low alarm for monitoring
Keyfeatures4:
Sliding glass doors for quick inventory checks
Keyfeatures6:
R290 Hydrocarbon refrigerant for eco-friendliness
Keyfeatures:
57" wide two-section design for high-capacity storage
Keyfeatures3:
ENERGY STAR® rated with R-290 refrigerant
Keyfeatures2:
All stainless steel for durable sanitation
short_description:
Continental Refrigerator D2RENSSSGD 57" two-section glass door reach-in has 52 cu. ft. capacity in a stainless steel cabinet with sliding glass doors.
Lead Time:
2 - 3 Business Days
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
Stop compromising storage integrity when duty demands consistent temperature control and clear product visibility. This two-section, 57-inch wide reach-in refrigerator delivers 52 Cu. Ft. of usable capacity, sliding glass doors for fast inventory checks, and a self-contained refrigeration system engineered for continuous service in food service operations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and remove all food. Wipe interior surfaces with a mild detergent and warm water; rinse and dry. Clean condenser coils monthly with a brush or vacuum to maintain ENERGY STAR® performance and reduce energy use. Degrease door tracks and glass with non-abrasive cleaner. Inspect and replace worn gaskets to prevent air leaks. Schedule professional service for refrigeration components annually to avoid breakdowns and ensure CSA and cETLus compliance.#@@#Additional Info#@#Continental Refrigerator D2RENSSSGD is a 57" wide, two-section reach-in fridge with 52 cu. ft.#@@#General Info#@#Description #@# Stop compromising storage integrity when duty demands consistent temperature control and clear product visibility. This two-section, 57-inch wide reach-in refrigerator delivers 52 Cu. Ft. of usable capacity, sliding glass doors for fast inventory checks, and a self-contained refrigeration system engineered for continuous service in food service operations. #@@# Exterior Durability#@# Constructed entirely of stainless steel, the cabinet, interior, and exterior resist corrosion and simplify sanitation routines. Surfaces withstand frequent cleaning cycles common in restaurants, hospitals, and campus kitchens. #@@# Sliding Glass Doors#@# Wide full-height sliding glass doors allow rapid access without swinging clearance, reducing traffic bottlenecks in tight line environments. Doors include cylinder locks to secure inventory during overnight hours. #@@# Refrigeration Performance#@# The top-mounted, self-contained refrigeration system uses R-290 hydrocarbon refrigerant with a 1/2 HP compressor to maintain stable temperatures across both sections. The unit delivers energy-efficient cooling while supporting frequent door openings typical of high-volume operations. #@@# Control and Monitoring#@# An electronic control with a digital display provides precise temperature readouts and settings, while a hi-low alarm notifies staff of out-of-range conditions for quick corrective action. CSA and cETLus certifications confirm compliance with recognized safety standards. #@@# Serviceability and Installation#@# Top-mounted compressor placement simplifies floor-level service access and reduces noise at operator height, aiding maintenance efficiency. The unit ships on 6-inch stainless steel legs and accepts standard 115v power via a NEMA 5-15P plug for straightforward installation. #@@# Energy and Compliance#@# ENERGY STAR® performance reduces operating costs compared to less efficient models, and NSF certification ensures compliance with commercial sanitation requirements. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Perform weekly coil cleaning with a soft brush and vacuum to maintain heat exchange efficiency. Inspect door gaskets monthly; replace seals showing cracks or compression to preserve temperature control. Defrost manually if ice exceeds 1/4 inch and verify drain lines remain clear. Calibrate electronic control quarterly and test hi-low alarm and door lock function. Use approved refrigerant handling procedures for R-290 and document all service actions for CSA and cETLus compliance.