Skip to main content

Continental Refrigerator DL1RS-SA 26" W One-Section Solid Door Reach-In Designer Line Refrigerator

Continental Refrigerator

Was: $8,824.00
Now: $7,807.85
(No reviews yet) Write a Review
SKU:
DL1RS-SA
Weight:
360.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
DL1RS-SA__1074
BTU/HR:
1940
Compressor HP:
1/4
Door Style:
Hinged
Door Type:
Solid
Exterior Finish:
Stainless Steel
Interior Finish:
Aluminum
Nema Plug Type:
NEMA 5-15P
No. of Shelves:
3
Number of Sections:
1
Refrigerant Type:
R-290
email_price:
no
Tags:
Refrigerator, Reach-In
Label Option type:
rectangles
Net Price:
7146.77
msrp_price:
no
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Reach-In Refrigerators and Freezers>>Reach-In Refrigerators
Allow to show add to cart:
Login or Add to Cart to See Price
call_price:
no
map_price:
yes
add_to_cart:
no
MAP Price:
8824
Manufacturer:
Continental Refrigerator
login_price:
yes
Product ID:
6f61fd2e-c00d-dd11-a23a-00304834a8c9
List Price:
20639
Taxonomy Weight:
360
Amps:
5.5
Phase:
1-Ph
Hertz:
60
Filter Construction:
Stainless Steel and Aluminum
Filter_Sections:
1
Filter_Voltage:
115 Volts
Filter_Door Type:
Solid
Filter_Refrigerant Type:
R-290
Filter_Construction:
Stainless Steel and Aluminum
Trigger BC Integration:
Y-6/19/2026_1:05PM
Primary Image:
DL1RS-SA.png
Sale Price:
7807.846225
Filter_Manufacturer:
Continental Refrigerator
Filter_Features:
Shallow Depth
other_types:
DL1RS-SA$One Door#@#DL2RS-SA$Two Door
specsheet:
Continental Refrigerator_DL1RS-SA.pdf
warranty:
Continental Refrigerator_DL1RS-SA_1.pdf
manual:
Continental Refrigerator_DL1RS-SA_2.pdf
Filter_Number of Doors:
1 Door
Number of Doors:
1
Voltage:
115v
NSF Certified:
Yes
cETLus Certified:
Yes
Number of Shelves:
3 Shelves
Capacity:
21 Cu. Ft.
Filter_Capacity:
11 - 29 Cubic Feet
Filter_Hinge Location:
Right
Filter_Compressor Location:
Top Mounted
Filter_NSF Listed:
Yes
Keyfeatures5:
Top-mounted 1/4 HP compressor
Keyfeatures4:
Full-height solid door with lock
Keyfeatures:
Self-contained R290 refrigeration for lower energy use
Keyfeatures3:
Stainless steel exterior, aluminum interior
Keyfeatures2:
21 Cu. Ft. capacity for storage
short_description:
Continental Refrigerator DL1RS-SA 26" solid door reach-in has 21 cu. ft. capacity with stainless steel exterior and aluminum interior for durable storage.
Ship From:
19020
Lead Time:
2 - 3 Business Days
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
Stop trading laboratory precision for commercial throughput. This reach-in refrigerator delivers consistent temperature control and robust storage in a compact footprint, allowing kitchens to maintain product integrity while optimizing floor space. County and campus foodservice operators gain a practical refrigeration platform engineered for continuous use and efficient maintenance.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug unit and remove food. Empty water or trays, then wipe interior with mild soap and warm water using a soft cloth. Clean condenser coils every month with a brush or coil cleaner to maintain efficiency. Scrub door gaskets and check seals; replace if cracked. Degrease exterior with non-abrasive cleaner. Sanitize food-contact surfaces with recommended sanitizer and let air dry. Dry all components before restoring power to prevent electrical faults.#@@#Additional Info#@#Continental Refrigerator DL1RS-SA 26" reach-in refrigerator offers 21 cu. ft.#@@#General Info#@#Description #@# Stop trading laboratory precision for commercial throughput. This reach-in refrigerator delivers consistent temperature control and robust storage in a compact footprint, allowing kitchens to maintain product integrity while optimizing floor space. County and campus foodservice operators gain a practical refrigeration platform engineered for continuous use and efficient maintenance. #@@# Shallow Depth#@# Engineered with a shallow depth cabinet, this unit reduces protrusion into aisles while preserving interior capacity, enabling tight kitchen layouts without sacrificing usable storage. Operators benefit from streamlined traffic flow and easier placement against counters or walls in constrained back-of-house environments. #@@# Stainless Steel Exterior#@# Constructed with a stainless steel exterior, the cabinet resists corrosion and simplifies daily sanitation procedures, supporting compliance with health codes. Maintenance teams save time during cleanings, and facility managers preserve appearance under heavy use. #@@# Aluminum Interior#@# The aluminum interior provides durable surfaces that dissipate moisture and promote uniform cooling distribution, reducing hotspots within the 21 Cu. Ft. refrigerated volume. Staff report improved shelf life for perishable stocks due to consistent internal conditions. #@@# Solid Full-Height Door#@# A full-height solid door with cylinder lock secures inventory and reduces temperature exchange compared with glass alternatives, delivering stable storage for sensitive items. Managers receive the dual benefit of controlled access and lower energy loss during service cycles. #@@# R290 Refrigerant#@# The system operates on R290 hydrocarbon refrigerant with a 1/4 HP compressor, delivering efficient thermodynamic performance and lower global warming potential than traditional refrigerants. Facility engineers gain a compact, energy-conscious refrigeration solution that meets modern regulatory expectations. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Maintain the Continental Refrigerator DL1RS-SA by cleaning condenser coils monthly to ensure heat exchange and reduce compressor load. Inspect the door gasket weekly for cracks and replace damaged seals to prevent cold-air loss. Sanitize interior surfaces with mild detergent and warm water; avoid abrasive cleaners. Verify drain lines are clear and flush with water monthly to prevent backup. Calibrate electronic control quarterly and test hi-low alarm functions after service.