Stop compromising line speed for control. This 4-way manifold with dual inlet ports streamlines draft setups by routing gas to multiple lines while preserving individual shutoff capability, enabling rapid service and simplified maintenance across high-volume bars, cafeterias, and stadium carts. Technicians install and configure this compact manifold to expand distribution with a minimal footprint and predictable pressure behavior.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug draft system and close gas supply. Remove manifold and inspect fittings for corrosion. Flush passages with warm, soapy water and rinse until clear. Use a soft brush on barbed inlets and 5/16" shutoff to remove buildup. Dry parts completely and reassemble, checking seals. Test for leaks and proper flow. Clean weekly to reduce bacterial risk, prevent grease fires, lower energy use, extend equipment life, and ensure CSA compliance.#@@#Additional Info#@#Beverage Air’s 402-262A 4-way manifold with two 5/16" barbed inlets and integrated shutoff ensures precise draft distribution for bars and kitchens, supports standard configurations, weighs 2 pounds, and meets CSA standards.#@@#General Info#@#Description #@#
Stop compromising line speed for control. This 4-way manifold with dual inlet ports streamlines draft setups by routing gas to multiple lines while preserving individual shutoff capability, enabling rapid service and simplified maintenance across high-volume bars, cafeterias, and stadium carts. Technicians install and configure this compact manifold to expand distribution with a minimal footprint and predictable pressure behavior.
#@@# Four Way Outlet#@#
Four distribution ports deliver consistent flow to four downstream lines, allowing simultaneous service to multiple taps without pressure loss when system sizing matches line length. Operators gain predictable pour rates and simplified troubleshooting because each outlet maintains symmetry and straightforward diagnostics.
#@@# Dual Inlet Design#@#
Two 5/16 inch barbed inlets accept parallel supply feeds to balance source load or enable redundant supply routing for continuous operation. Engineers configure dual inputs to halve supply resistance or to permit staged maintenance without shutting down the entire run.
#@@# Individual Shutoff#@#
Integrated 5/16 inch shutoff lets staff isolate a single branch without affecting other lines, reducing downtime during line changeovers or keg swaps. Maintenance teams perform targeted service while the rest of the system remains active, preserving service continuity.
#@@# Barbed Connections#@#
Barbed fittings secure tubing with a mechanical hold, minimizing slip and gas loss under standard operating pressures when teams apply proper clamps. Field technicians appreciate the rapid assembly and the reduced need for specialized swaging tools.
#@@# Compact Footprint#@#
Low-profile housing fits easily inside cramped underbar cavities and cooler compartments, enabling flexible placement near regulators or distribution manifolds. Installers route lines with shorter runs, which limits pressure drop and improves long-run temperature control.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Beverage Air 402-262A manifold weekly and verify all fittings for tightness to prevent leaks. Drain condensate and flush lines monthly with appropriate cleaner to remove buildup. Replace worn gaskets or barbed inlets immediately to maintain seal integrity. Lubricate shutoff linkage quarterly using food-grade lubricant. Record maintenance in a log and schedule professional CSA inspection annually to ensure compliance and reliable draft performance.