Skip to main content

Berner IDC14-4144A-3 144" W Un-Heated 4 Motors Interior Mounting Industrial Series Direct Drive Air Curtain - 208 Volts 3-Ph

Berner

$5,830.50
(No reviews yet) Write a Review
SKU:
IDC14-4144A-3
Weight:
473.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
IDC14-4144A-3__6015
Width (side - side):
144" - 155"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
4485.00
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
5830.50
Manufacturer:
Berner
login_price:
no
List Price:
8970
Trigger BC Integration:
Y-3/19/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
473
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Voltage:
208 Volts
Filter_Width:
130 - 159 Inches
Filter_Horsepower:
1 HP
Primary Image:
Berner_IDC14-4144A-3.png
specsheet:
Berner_IDC14-4144A-3.pdf
warranty:
Berner_IDC14-4144A-3_1.pdf
manual:
Berner_IDC14-4144A-3_2.pdf
Sale Price:
5830.50
Filter_Made in America:
Yes
Voltage:
208v
is free shipping:
Yes
Keyfeatures5:
cULus certified, MADE IN USA
Keyfeatures4:
208 volts, 3-Ph electrical
Keyfeatures6:
Designed for insect protection up to 12 feet
Keyfeatures:
144" wide industrial air curtain for 14 ft openings
Keyfeatures3:
Interior mounting for separation
Keyfeatures2:
Un-heated direct drive with four 1 HP motors
short_description:
Berner IDC14-4144A-3 air curtain mounts inside doorways for separation up to 14 feet high and insect protection to 12 feet, using four 1 HP motors in a 144" housing.
Lead Time:
2 - 3 Business Days
Adding to cart… The item has been added
Stop compromising separation performance for energy efficiency. This industrial air curtain ensures sustained environmental control across large openings while accommodating three-phase 208 volt power systems commonly found in commercial facilities. This design enables continuous operation with predictable electrical load and consistent airflow delivery.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior housing and inlet screen daily with mild detergent and a soft cloth; rinse and dry. Use a non-abrasive cleaner on stainless trim and avoid excess water near motors. Inspect and clear debris from inlet screen weekly to maintain airflow and pest deterrence. Sanitize high-touch controls and door surrounds after peak service to prevent contamination transfer between staff and customers. Document cleaning and inspections to support CSA compliance and health inspections.#@@#Additional Info#@#Berner’s IDC14-4144A-3 air curtain mounts inside, spans 144", and protects openings up to 14 ft. Unheated, it uses four 1 HP motors at 208 volts, 3-Ph, for environmental separation and insect control. cULus certified, made in USA.#@@#General Info#@#Description #@# Stop compromising separation performance for energy efficiency. This industrial air curtain ensures sustained environmental control across large openings while accommodating three-phase 208 volt power systems commonly found in commercial facilities. This design enables continuous operation with predictable electrical load and consistent airflow delivery. #@@# Four Motor Power#@# This unit utilizes four 1 HP direct drive motors to provide high airflow for openings up to 14 feet in height, ensuring effective temperature and contaminant separation in kitchens, loading docks, or retail entrances. The four motors offer redundancy, allowing the system to maintain partial performance if one motor requires service. #@@# Designed For Interior Mounting#@# Engineers recommend interior mounting to concentrate the air stream at the door plane and simplify wiring to existing 208 volt, 3-Ph circuits. This approach reduces installation labor in retrofit projects. Interior placement also allows easier access for routine inspections and motor service without the need for external scaffolding. #@@# Un-Heated Operation#@# The un-heated design eliminates on-board heat sources, reducing electrical demand and preventing unnecessary warming of conditioned spaces. This feature is ideal for buildings that already control indoor temperature using HVAC systems. Technicians can integrate the curtain with existing heating controls when supplemental heat is necessary. #@@# Door Height Coverage#@# Rated for doors up to 14 feet for environmental separation and up to 12 feet for insect protection, the curtain provides a consistent barrier for large commercial openings. Manufacturers size the unit to match wide spans, featuring a 144-inch nominal width that supports continuous coverage without multiple staggered sections. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect motor mounts monthly and tighten fasteners to specified torque values. Clean inlet screen and housing weekly using a vacuum and non-abrasive brush to prevent airflow restriction. Lubricate motor bearings per manufacturer schedule and replace seals showing wear. Verify electrical connections on 208 volts, 3-Ph supply and confirm CSA or cUlus labels remain legible. Balance airflow after filter maintenance and document service intervals to support uptime and regulatory compliance.