Skip to main content

Berner ARC16-3108A-1 108" W Un-Heated Architectural Series Recessed 16 Air Door - 120 Volts 1-Ph

Berner

$5,911.75
(No reviews yet) Write a Review
SKU:
ARC16-3108A-1
Weight:
343.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
ARC16-3108A-1__6015
Width (side - side):
108" - 119"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
4547.50
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
5911.75
Manufacturer:
Berner
login_price:
no
List Price:
9095
Trigger BC Integration:
Y-3/19/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
343
cULus Certified:
Yes
Phase:
1-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Speeds:
2-Speeds
Filter_Voltage:
120 Volts
Filter_Width:
85 - 109 Inches
Filter_Horsepower:
1 HP
Primary Image:
Berner_ARC16-3108A-1.png
specsheet:
Berner_ARC16-3108A-1.pdf
warranty:
Berner_ARC16-3108A-1_1.pdf
manual:
Berner_ARC16-3108A-1_2.pdf
Sale Price:
5911.75
Filter_Made in America:
Yes
Voltage:
120v
is free shipping:
Yes
Keyfeatures5:
120 volts, single-phase, cULus certified
Keyfeatures4:
Hinged white aluminum access panel
Keyfeatures6:
Made in USA, for commercial use
Keyfeatures:
108" recessed un-heated air door for 16' openings
Keyfeatures3:
Two-speed Intelliswitch controller
Keyfeatures2:
Three 1 HP motors for airflow
short_description:
Berner ARC16-3108A-1 recessed air door spans 108" and features three 1 HP motors with two speeds and an Intelliswitch controller for airflow control. It mounts for openings up to 16 feet, weighs 343 pounds, and ships made in USA.
Lead Time:
2 - 3 Business Days
Adding to cart… The item has been added
Stop sacrificing entrance control for convenience. This unheated recessed air door delivers targeted airflow for openings up to 16 feet, combining robust motor capacity and controllable speeds to maintain internal climates while minimizing infiltration and energy loss. Designed for architectural installations, the unit fits a 108-inch opening and integrates seamlessly into finished interiors without protruding housings.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe air curtain housing and grille daily with a microfiber cloth and mild detergent; rinse and dry. Remove access panel monthly, inspect and vacuum motor compartments and fan blades; tighten hardware and replace worn seals. Sanitize high-touch areas (control switches, handles) with an EPA-registered disinfectant per label dwell time. Regular cleaning prevents contamination, supports health code compliance, and extends fixture service life.#@@#Additional Info#@#Berner ARC16-3108A-1 recessed air door spans 108" and provides a 16 ft.#@@#General Info#@#Description #@# Stop sacrificing entrance control for convenience. This unheated recessed air door delivers targeted airflow for openings up to 16 feet, combining robust motor capacity and controllable speeds to maintain internal climates while minimizing infiltration and energy loss. Designed for architectural installations, the unit fits a 108-inch opening and integrates seamlessly into finished interiors without protruding housings. #@@# Motor Configuration#@# Three 1 HP motors provide concentrated airflow across the full 108-inch span, producing consistent curtain velocity that deters drafts and airborne contaminants. Each motor operates on 120 volts, single-phase power, enabling straightforward wiring to common electrical supplies. #@@# Speed Control#@# A two-speed Intelliswitch controller allows quick selection between higher throughput for peak traffic and lower output for steady-state operation. Facility managers can adjust air volume to match occupancy patterns and reduce unnecessary runtime. #@@# Installation Profile#@# The recessed architectural design minimizes visual impact and preserves ceiling lines for finished spaces. The hinged white aluminum bottom access panel enables service teams to reach internal components without removing the unit from the opening. #@@# Mounting Capacity#@# Engineered for mounting heights up to 16 feet, the unit generates effective air curtains that span greater vertical openings found in loading docks and institutional entries. Designers gain flexibility in specifying the unit for tall storefronts, cafeterias, and hospital entries. #@@# Certification and Origin#@# Meets cULus requirements and ships from a USA facility, offering documented compliance and domestic manufacturing traceability. Operators receive a certified product intended for commercial environments. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Maintain the Berner ARC16-3108A-1 air door by scheduling biweekly visual inspections of motor mounts, fan blades, and the Intelliswitch controller for proper operation. Remove debris from inlet and outlet grills and vacuum coils monthly to preserve airflow. Lubricate motor bearings per manufacturer intervals and verify electrical connections at 120 volts for tightness. Replace worn seals and test two-speed function after service to ensure reliable performance.