Stop sacrificing control for coverage. This unheated architectural air door delivers targeted airflow across wide openings while sustaining continuous operation for demanding facilities, enabling efficient separation of interior environments without heat addition. Designed for mounting at heights up to 16 feet, this recessed unit pairs two 1 HP motors with a two-speed control to maintain consistent performance in institutional and commercial settings.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch zones (menu covers, shakers, chair backs, door handles) with a detergent cloth, then sanitize per label directions. Clean dining booths, shelving, and floor edges daily to remove crumbs and spills that attract pests. Inspect and tighten fasteners on chairs weekly. Record procedures for health inspections to show compliance and protect food from cross-contamination.#@@#Additional Info#@#Berner ARC16-2108A-3 recessed 108" un‑heated air door delivers 16 ft. mounting height coverage with two 1 HP motors, two-speed Intelliswitch control, hinged white aluminum access panel, 480 volts 3-Ph power, cULus certified, MADE IN USA, 291 pounds.#@@#General Info#@#Description #@#
Stop sacrificing control for coverage. This unheated architectural air door delivers targeted airflow across wide openings while sustaining continuous operation for demanding facilities, enabling efficient separation of interior environments without heat addition. Designed for mounting at heights up to 16 feet, this recessed unit pairs two 1 HP motors with a two-speed control to maintain consistent performance in institutional and commercial settings.
#@@# Two Motor Design#@#
Dual 1 HP motors supply robust airflow and redundancy, preserving operation if one circuit experiences issues. Engineers specified two motors to distribute load and reduce stress on each drive, improving uptime for long shifts.
#@@# Variable Speed Control#@#
An Intelliswitch controller provides two operating speeds to match traffic volume and thermal requirements, allowing operators to prioritize airflow or energy savings. Technicians can switch modes quickly to adapt to varying door cycles without complex adjustments.
#@@# Recessed Architectural Fit#@#
Recessed construction yields a low-profile installation that integrates with ceiling cavities and preserves aesthetic lines in public spaces. Architects and facility managers gain a discreet solution that maintains corridor clearance and sightlines.
#@@# High Mount Capability#@#
Rated for mounting heights up to 16 feet, this unit projects airflow over tall entrances and loading bays, maintaining separation across large vertical distances. Specifying this height capacity reduces cross-contamination risk and stabilizes indoor conditions in multi-story lobbies and service entrances.
#@@# Industrial Electrical Specification#@#
Configured for 480 volts 3-Ph operation, the unit supports commercial electrical systems common in large campuses and institutional kitchens. Electrical compatibility simplifies integration into existing three-phase panels and minimizes transformer requirements.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect fan blades monthly and remove debris to maintain airflow and reduce motor load. Lubricate motor bearings per manufacturer intervals with a compatible lubricant and follow lockout/tagout procedures. Tighten electrical connections and verify 480 volts, 60 hertz, 3-Ph supply at terminals to prevent overheating. Replace damaged access panels and seals to retain flow. Balance mounting hardware and confirm the unit sits level for openings up to 16 feet.