Stop sacrificing temperature control for throughput. This heated recessed air door combines sustained airflow and electric heating to preserve interior conditions while managing high-traffic openings up to 16 feet tall. Operations can maintain comfort and sanitation without constant HVAC adjustments. Food service managers and facility directors will find a reliable solution that integrates into ceiling cavities for a discreet profile and continuous performance under heavy use.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch zones (menu covers, shakers, chair backs, door handles) with a neutral detergent and microfiber cloth, then apply EPA-registered sanitizer. Clean booth crevices and under shelves with a vacuum or stiff brush. Remove spills immediately to prevent stains and pests. Schedule daily surface cleaning and weekly deep clean; document tasks for health inspections. Regular cleaning prevents cross-contamination, shapes customer perception, and extends furniture life.#@@#Additional Info#@#Berner ARC16-2072E-2-3 72" heated air door offers 16 air changes for 16 ft openings, with two 1 HP motors and Intelliswitch control on 208 volts, 3-Ph; provides 28 kW heat, cULus certified, 225 pounds, hinged white aluminum panel, made in USA.#@@#General Info#@#Description #@#
Stop sacrificing temperature control for throughput. This heated recessed air door combines sustained airflow and electric heating to preserve interior conditions while managing high-traffic openings up to 16 feet tall. Operations can maintain comfort and sanitation without constant HVAC adjustments. Food service managers and facility directors will find a reliable solution that integrates into ceiling cavities for a discreet profile and continuous performance under heavy use.
#@@# Recessed Installation#@#
Engineers designed the unit for recessed mounting, allowing installation within a ceiling cavity to preserve architectural lines. Technicians will appreciate the hinged white aluminum bottom access panel that permits service and routine inspection without complete removal.
#@@# Two Motors#@#
Two 1 HP motors deliver the defined airflow necessary for wide openings, enabling sustained air separation across the full 72-inch span. Maintenance teams benefit from redundant motor capacity that reduces load per motor and extends operational life under continuous duty cycles.
#@@# Two Speeds#@#
The two-speed motor configuration simplifies control of airflow volume, providing high output during peak traffic and reduced flow for energy savings during off-peak periods. Facility managers can program cycling to match operational schedules and limit unnecessary electrical draw.
#@@# Electric Heating#@#
The 28 kW electric heating element supplies immediate thermal support to the airstream, maintaining interior temperature gradients and reducing infiltration losses. Engineers will note that the electric design eliminates combustion concerns and supports installations in sensitive environments.
#@@# Controller Integration#@#
An Intelliswitch controller governs motor speeds and heating stages, delivering precise, repeatable settings that technicians can adapt to varied door heights and occupancy patterns. Controls support straightforward commissioning and consistent operational behavior.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air curtain weekly. Remove dust from inlet and outlet grilles with a soft brush or vacuum. Schedule monthly lubrication for motor bearings with approved lubricant. Tighten electrical connections every three months to prevent heating. Replace intake filters when pressure drop exceeds limits or every six months. Verify Intelliswitch settings after service and test two-speed functionality. Ensure the bottom access panel seals correctly; re-align brackets if vibration loosens them.