Stop sacrificing control for convenience. This industrial air door delivers targeted, high-velocity airflow across wide openings to maintain interior conditions, reduce infiltration, and support efficient climate control in demanding facilities. Engineers designed the unit for commercial installation, combining robust motors, a recessed architectural profile, and a serviceable access panel for fast onsite maintenance.
LongDescription#@#NA#@@#Cleaning Instructions#@#Clean high-touch areas like door handles, chair backs, menus, and shakers daily to prevent germ transfer and customer contamination. Use a detergent wipe or mild soap solution, scrub visible soil, then apply an EPA-registered sanitizer per label contact time. Rinse food-contact items when required. Inspect crevices and under booths weekly; remove crumbs and residue to deter pests. Document cleaning times and products for health inspections and consistent customer perception.#@@#Additional Info#@#Berner ARC16-2072A-1 recessed air door, 72" width, un-heated, uses two 1 HP motors with two-speed Intelliswitch control, mounts up to 16 ft. openings, operates on 120 volts 1-Ph at 60 Hz, cULus certified and made in USA.#@@#General Info#@#Description #@#
Stop sacrificing control for convenience. This industrial air door delivers targeted, high-velocity airflow across wide openings to maintain interior conditions, reduce infiltration, and support efficient climate control in demanding facilities. Engineers designed the unit for commercial installation, combining robust motors, a recessed architectural profile, and a serviceable access panel for fast onsite maintenance.
#@@# Two Speed Motors#@#
Two 1 HP motors provide high velocity output and redundancy for continuous operation. Operators select a low or high setting to balance airflow performance and energy use based on occupancy and exterior conditions.
#@@# Recessed Architectural Design#@#
A recessed housing integrates with ceiling or header cavities to preserve door aesthetics and clearances. Installers adapt the unit to 72-inch openings while keeping a low visible profile in public corridors and hospitality spaces.
#@@# Un-Heated Configuration#@#
The un-heated design eliminates heating elements where temperature control relies on HVAC systems or where freeze risk remains low. Facility managers avoid unnecessary electrical heating loads while retaining focused air separation at openings.
#@@# Intelliswitch Controller#@#
The included Intelliswitch controller simplifies mode selection and provides consistent fan sequencing. Technicians use the controller to set two-speed operation and streamline commissioning across multiple units.
#@@# Hinged Access Panel#@#
A hinged white aluminum bottom access panel allows rapid access to internal components without full removal. Maintenance crews perform motor and wiring inspections quickly, reducing downtime and service labor costs.
#@@# Installation Range#@#
The assembly fits mounting heights up to 16 feet and spans 72-inch openings with a declared model width of 72. Contractors reference the 26-inch depth and 15-inch housing height when coordinating structural rough-ins and clearances.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air curtain monthly and remove dust from intake grilles to preserve airflow. Tighten electrical connections and mounting hardware quarterly. Lubricate motor bearings per manufacturer intervals and replace filters when pressure drop exceeds specification. Verify two-speed operation and Intelliswitch controller function during routine checks. Confirm bottom access panel seals and hinge alignment. Document maintenance actions and record hours for warranty compliance.