Stop sacrificing doorway control for energy efficiency. This electric heated recessed air door provides consistent airflow management and thermal protection for high-traffic openings, designed to perform at mounting heights up to 16 feet while operating on 208 volts, 3-Ph power. Facility managers and operators will benefit from a robust, code-listed unit that balances thermal output and airflow, reducing infiltration and maintaining conditioned space.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch zones (menu covers, shakers, chair backs, door handles) with a cloth and EPA-registered disinfectant; follow dwell time on label. Clean booth crevices and under shelves with vacuum then detergent to remove crumbs and grease. Rinse nonporous surfaces, dry thoroughly. Inspect weekly for damage and residue. Regular cleaning prevents cross-contamination, deters pests, preserves furnishings, and supports health-code compliance.#@@#Additional Info#@#Berner’s ARC16-1048E-2-3 heated air door offers 48" coverage with a 1 HP motor, 14 kW at 208 volts, and mounts up to 16 ft. It's cULus certified, made in the USA, and weighs 151 pounds.#@@#General Info#@#Description #@#
Stop sacrificing doorway control for energy efficiency. This electric heated recessed air door provides consistent airflow management and thermal protection for high-traffic openings, designed to perform at mounting heights up to 16 feet while operating on 208 volts, 3-Ph power. Facility managers and operators will benefit from a robust, code-listed unit that balances thermal output and airflow, reducing infiltration and maintaining conditioned space.
#@@# Motor Performance#@#
A single 1 HP motor delivers the primary motive force, and two operating speeds allow staff to match airflow to occupancy and weather conditions. Operators can reduce noise and energy consumption at lower demand while retaining full output when pressure differentials necessitate maximum throughput.
#@@# Heating Capacity#@#
The unit provides 14 kW of electric heat to maintain doorway temperatures and limit cold air penetration at large openings. Maintenance teams will find that electric heat simplifies integration with existing electrical infrastructure and eliminates on-site combustion risks.
#@@# Control Interface#@#
An Intelliswitch controller offers programmable operation and responsive adjustments to motor speed and heater stages for reliable performance. Technicians will appreciate repeatable settings that streamline commissioning and reduce time spent troubleshooting inconsistent operation.
#@@# Installation Form Factor#@#
A recessed architectural configuration fits within standard 48-inch openings and aligns with widths from 48 to 59 inches, enabling flush mounting that preserves aesthetics. Architects and installers will benefit from a concealed profile that minimizes visual impact in finished openings.
#@@# Access and Serviceability#@#
A hinged white aluminum bottom access panel provides direct service access to internal components without the need to remove the entire assembly.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air curtain weekly and tighten hardware to prevent vibration failure. Replace filters quarterly or sooner if debris appears; log changes in maintenance records. Lubricate motor bearings as per manufacturer intervals and check dual-speed operation on both settings. Test the Intelliswitch controller monthly and log error codes. Clean intake and outlet grilles with a vacuum and mild detergent to maintain airflow and heating efficiency. Ensure three-phase connections are torque-checked.