When operational demands escalate, this indoor walk-in cooler box delivers consistent temperature control and robust construction to support high-volume cold storage needs. Designed for outdoor installation yet configured solely as an indoor box, the unit offers a balance of thermal performance and durable materials that streamline workflow and protect stored product integrity. Facility managers gain a modular, code-ready solution that integrates seamlessly with refrigeration systems while reducing installation complexity and long-term maintenance requirements.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug equipment and remove food and debris. Scrub surfaces with mild detergent and warm water, rinsing thoroughly. Clean condenser coils and vents with a soft brush to remove grease and dust. Degrease oven interiors and hood filters with an approved solvent, then rinse and dry. Sanitize food contact areas with an NSF-approved solution per label dwell time. Inspect seals and hinges; replace worn parts. Dry surfaces completely before restoring power and restocking.#@@#Additional Info#@#AmeriKooler QC081277**F-O indoor walk-in cooler measures 144" W x 96" D x 91" H. It has a 600 lbs/sq. ft. NSF aluminum floor, 4" AK-XPS4 insulation (R-29), and a flush self-closing door.#@@#General Info#@#Description #@#
When operational demands escalate, this indoor walk-in cooler box delivers consistent temperature control and robust construction to support high-volume cold storage needs. Designed for outdoor installation yet configured solely as an indoor box, the unit offers a balance of thermal performance and durable materials that streamline workflow and protect stored product integrity. Facility managers gain a modular, code-ready solution that integrates seamlessly with refrigeration systems while reducing installation complexity and long-term maintenance requirements.
#@@# Panel Insulation#@#
The unit utilizes 4 inches of AK-XPS4 insulation, providing R-29 for coolers and R-32 for freezers to maintain internal temperature stability under heavy load. High thermal resistance reduces run time for attached refrigeration equipment and limits temperature drift during peak traffic periods.
#@@# Corrosion Resistant Finish#@#
Acrylume coated 26-gauge stucco embossed steel covers both interior and exterior surfaces to resist corrosion in high humidity environments. This protective finish minimizes surface damage from routine cleaning and extends service life in demanding back-of-house conditions.
#@@# Reinforced Flooring#@#
The NSF aluminum floor supports uniformly distributed loads rated at 600 pounds per square foot, capable of handling shelving, carts, and pallet traffic without compromise. The heavy-duty floor capacity enables flexible layout choices and reduces the risk of structural stress under frequent loading cycles.
#@@# Door Hardware#@#
The flush self-closing door pairs with super cam rise spring-assisted hinges and a door closer to promote reliable sealing and controlled operation. Consistent door performance helps preserve set points and reduces energy loss from prolonged open periods.
#@@# Monitoring Controls#@#
A digital LED thermometer with a pilot light switch provides clear temperature readout and status indication for staff monitoring cold storage.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect door gaskets weekly and replace seals that show cracks or compression to prevent air leaks. Clean condenser coils monthly; disconnect power, brush debris, and vacuum fins to maintain thermal transfer. Wash interior panels with mild detergent and warm water; rinse and dry to prevent corrosion on Acrylume surfaces. Verify floor anchors and leveling quarterly and confirm NSF aluminum floor loading remains intact. Log maintenance actions and retain CSA and UL documentation.