Skip to main content

AmeriKooler QC060677**FBRC-O-448A 72" W x 72" D x 91" H Acrylume with Floor Outdoor Quick Ship Walk-In Cooler

AmeriKooler

Was: $10,890.00
Now: $10,505.74
(No reviews yet) Write a Review
SKU:
QC060677**FBRC-O
Weight:
1,266.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
QC060677**FBRC-O-448A__16265
Finish:
Acrylume
Floor:
With Floor
Installation:
Outdoor
Nominal height:
7'-7"
Nominal Long Side:
6'
Nominal Short Side:
6'
Voltage:
208/230v
email_price:
no
Tags:
Walk In Cooler, Modular, Remote
Label Option type:
rectangles
Net Price:
9905.18
msrp_price:
no
Ship From:
33010
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Walk-In Refrigeration>>Walk-In Coolers / Refrigerator
call_price:
no
map_price:
no
Mfr Toll Free:
(800) 627-5665
Freight Class:
92.5
Packed By:
1 Each
add_to_cart:
no
MAP Price:
10890
Manufacturer:
AmeriKooler
login_price:
Yes
Product ID:
a44815e4-e011-45b0-b216-0cc727d9fb0c
List Price:
23170
Taxonomy Weight:
1266
Phase:
1-Ph
Hertz:
60
Filter_Width:
51 - 100 Inches
Filter_Usage:
Outdoor
Filter_Height:
51 - 100 Inches
Trigger BC Integration:
Y-3/19/2026_6:00PM
Primary Image:
AmeriKooler_QC060677 FBRC-O.png
NSF Certified:
Yes
Made in USA:
Yes
Filter_Manufacturer:
AmeriKooler
Filter_Depth:
51 - 100 Inches
specsheet:
AmeriKooler_QC060677 FBRC-O.pdf
Sale Price:
10505.74
Filter_Voltage:
208/230 Volts
warranty:
AmeriKooler_QC060677 FBRC-O_1.pdf
UL Certified:
Yes
Filter_Refrigeration Type:
Remote
Filter_NSF Listed:
Yes
Filter_Made in America:
Yes
Filter_Refrigerant Type:
R-448A
Refrigerant Type:
R-448A
Refrigeration Type:
Remote
Keyfeatures5:
1/2 HP compressor for efficient control
Keyfeatures4:
Includes floor for easy installation
Keyfeatures6:
Made in USA with quick-ship availability
Keyfeatures:
Outdoor-rated Acrylume for corrosion resistance
Keyfeatures3:
Remote R-448A refrigeration compatible
Keyfeatures2:
72" W x 72" D x 91" H for compact planning
Filter_Features:
LED Lighting
short_description:
AmeriKooler QC060677**FBRC-O-448A outdoor walk-in cooler measures 72" W x 72" D x 91" H with an acrylume finish and built-in floor, designed for remote R-448A refrigeration and 1/2 HP operation.
Lead Time:
1-2 Weeks
Allow to show add to cart:
Login or Add to Cart to See Price
is free shipping:
Yes
Adding to cart… The item has been added
Built to accommodate heavy traffic while ensuring optimal temperature control, this outdoor walk-in cooler provides reliable refrigeration performance for both institutional and commercial kitchens. Designed for modular installation, the unit combines Acrylume panels with an integral floor, creating a robust, weather-resistant cold storage solution that ships quickly and requires minimal on-site modifications.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug equipment before cleaning. Remove all food and removable parts. Use mild detergent and warm water to scrub interior panels, door seals, and floor; rinse and dry. Clean condenser coils and fans to improve efficiency. Degrease oven hoods, vents, and filters to reduce fire risk. Sanitize food contact surfaces with an approved solution and let air dry. Inspect seals and components for wear and repair promptly to avoid breakdowns and inspection failures.#@@#Additional Info#@#AmeriKooler’s QC060677**FBRC-O-448A outdoor cooler measures 72" W x 72" D x 91" H, has an Acrylume finish, built-in floor, and R-448A refrigeration at 208/230 volts, 60 Hz, 1-Ph with 1/2 HP, UL and NSF certified, weighs 1,266 pounds.#@@#General Info#@#Description #@# Built to accommodate heavy traffic while ensuring optimal temperature control, this outdoor walk-in cooler provides reliable refrigeration performance for both institutional and commercial kitchens. Designed for modular installation, the unit combines Acrylume panels with an integral floor, creating a robust, weather-resistant cold storage solution that ships quickly and requires minimal on-site modifications. #@@# Panel Construction#@# Acrylume panels offer rigid thermal protection and corrosion resistance, making them ideal for outdoor installations. The modular sections are engineered for easy assembly, which reduces onsite labor and guarantees consistent R-value throughout the enclosure. #@@# Floor Integration#@# This unit features a built-in floor that can support heavy loads and simplifies product handling. Technicians will appreciate the integrated floor, which allows for quicker finishing and fewer sealing steps during installation. #@@# Remote Refrigeration#@# The system utilizes a remote refrigeration configuration with R-448A refrigerant, aligning with current thermodynamic and environmental standards. Operators benefit from quieter interior operation and flexible equipment placement, as the condensing unit is mounted away from high-traffic areas. #@@# Electrical Compatibility#@# The cooler operates on 208/230 volts at 60 hertz and is compatible with a 1-Ph power supply, aligning with common commercial electrical services. Facilities staff can plan circuits and breakers without needing special phase conversions or frequency adjustments. #@@# Capacity and Dimensions#@# The nominal footprint measures 72 inches by 72 inches, with a height of 7'-7", resulting in a compact 6' x 6' cold room suitable for back-of-house storage. Managers can accurately estimate storage volume and rack layouts based on the provided exterior dimensions. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#Upon confirmation of completed payment, Culinary Depot will ship and deliver the package.#@@#Maintenance Guide#@#Inspect seals weekly and replace damaged gaskets to maintain thermal efficiency and reduce energy use. Defrost evaporator coils monthly and remove ice with a plastic scraper to protect fins. Clean condenser coils and fan blades every three months using coil brush and low-pressure air; disconnect power before service. Verify refrigerant lines and fittings for leaks and consult certified technician for R-448A handling. Level unit and torque anchor bolts annually to preserve floor integrity.