Stop sacrificing capacity for control. This outdoor acrylume floorless walk-in cooler combines robust refrigeration and modular construction to support high-throughput operations while maintaining consistent medium-temperature performance. Designed for food service professionals, the unit delivers dependable cooling, simplified service access, and seasonal reliability in exposed installations.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug equipment and remove contents. Scrape visible debris, then wash interior surfaces with a mild detergent solution using a soft cloth. Rinse with clean water and dry fully. Clean condenser coils every month; use a brush or vacuum to remove dust. Degrease ovens and vents with a commercial degreaser to reduce fire risk. Inspect seals and hinges; tighten or replace as needed. Record each cleaning to meet CSA and health inspection standards.#@@#Additional Info#@#American Panel's 8X10C-O outdoor cooler measures 93" W x 87.75" H x 116" D.#@@#General Info#@#Description #@#
Stop sacrificing capacity for control. This outdoor acrylume floorless walk-in cooler combines robust refrigeration and modular construction to support high-throughput operations while maintaining consistent medium-temperature performance. Designed for food service professionals, the unit delivers dependable cooling, simplified service access, and seasonal reliability in exposed installations.
#@@# Door Configuration#@#
A hinged door with camlift hinges provides secure sealing and smooth operation. Technicians can access the interior easily for cleaning and maintenance, reducing downtime and labor during peak service periods.
#@@# Construction Materials#@#
Acrylume interior and exterior panels resist corrosion in outdoor environments. Operators gain long-term surface integrity that withstands moisture and routine cleaning without compromising insulation performance.
#@@# Floorless Design#@#
The floorless configuration installs over a vinyl screed to accommodate existing site flooring. Contractors preserve site drainage and avoid costly concrete modifications while maintaining proper thermal boundaries.
#@@# Refrigeration Package#@#
A 3/4 HP hermetic pre-charged remote R-448A system delivers medium-temperature control to maintain +35° F conditions. Facility engineers benefit from the factory-matched condensing unit and evaporator electrical ratings, 208v/60/1-ph at 12.7 amps and 1 amp respectively, for predictable load planning.
#@@# Weather Protection#@#
A vinyl membrane rain roof and winterization controls provide seasonal resilience for outdoor placement. Facility managers reduce weather-related service calls and ensure stable operation through temperature swings.
#@@# Controls and Monitoring#@#
The assembly ships with a Heatcraft Quick Response Controller standard, plus a dial thermometer and a vapor-proof light for basic monitoring and safe interior illumination. Staff can verify setpoints quickly and troubleshoot refrigeration responses with accessible readouts.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser coils every 3 months; remove dust with a brush and vacuum for efficiency. Check door camlift hinges and gaskets weekly for wear; tighten fasteners and replace leaking seals. Verify thermostat calibration monthly; record temperatures and adjust dial thermometer to maintain +35° F. Flush drain lines quarterly to prevent backups. Service R-448A circuits annually and check electrical connections at 208v panels. Winterize outdoor roofs and seal acrylume seams before freeze.