Stop compromising storage flexibility for site constraints. This outdoor combination cooler/freezer delivers a balanced 50/50 split of controlled low and medium temperature zones in a single integrated unit, enabling consistent cold chain management while saving on footprint and installation complexity. It pairs a sealed low-temperature system rated to -10° F with a medium-temperature circuit set to 35° F, providing distinct environments for frozen and chilled goods without cross-interference.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug electrical power and lock out circuits before cleaning. Remove food and debris; scrub interior surfaces with a mild detergent solution and a soft cloth. Rinse with clean water and dry thoroughly to prevent bacterial growth. Clean condenser coils and evaporator fins with a coil brush monthly to maintain efficiency and lower utility costs. Degrease door gaskets and hinges; inspect seals and replace worn parts to avoid leaks and failures.#@@#Additional Info#@#American Panel's 6X12-O outdoor Acrylume walk-in cooler/freezer measures 139" W x 90" H with a 50/50 split, 4" urethane freezer floor panels, and a floorless cooler.#@@#General Info#@#Description #@#
Stop compromising storage flexibility for site constraints. This outdoor combination cooler/freezer delivers a balanced 50/50 split of controlled low and medium temperature zones in a single integrated unit, enabling consistent cold chain management while saving on footprint and installation complexity. It pairs a sealed low-temperature system rated to -10° F with a medium-temperature circuit set to 35° F, providing distinct environments for frozen and chilled goods without cross-interference.
#@@# Panel Construction#@#
Acrylume interior and exterior panels provide corrosion resistance and smooth surfaces for cleaning. The foamed-in-place 4" urethane floor panels in the freezer ensure thermal integrity, while a vinyl screed floorless solution in the cooler reduces installation time on prepared concrete pads.
#@@# Temperature Control#@#
The system uses a dual hermetic pre-charged remote quick-connect R-448a refrigeration arrangement with a Heatcraft Quick Response Controller supplied as standard. Operators obtain stable setpoints for -10° F in the freezer and 35° F in the cooler, with winterization controls and a dial thermometer for local verification.
#@@# Door And Access#@#
A hinged door equipped with camlift hinges facilitates frequent traffic and reduces wear on seals, supporting high-use environments. Vapor-proof lighting inside the unit maintains visibility for inventory tasks while minimizing moisture-related failures.
#@@# Refrigeration Power#@#
The cooler circuit uses a 115v/60/1-ph condensing unit drawing 14.8 amps and a 115v evaporator motor at 0.5 amps, while the freezer circuit specifies a 208v/60/1-ph condensing unit at 12.6 amps plus evaporator components drawing 0.9 amps for fans and 4.3 amps for heaters. Facilities planners can size electrical feeds and remote condensing placement based on these nominal service loads.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Perform weekly visual inspections of seals, hinges and panel joints to detect gaps or corrosion. Service condenser coils monthly; remove debris and clean with coil cleaner to maintain heat transfer. Drain and inspect evaporator pans biweekly; clear condensate drains and verify heater operation. Calibrate thermostats quarterly and log temperature differentials for cooler and freezer. Lubricate camlift hinges semiannually and verify winterization controls before cold months.