Skip to main content

Advance Tabco K-57 Welded Field Joint

Advance Tabco

Was: $194.00
Now: $174.60
(No reviews yet) Write a Review
SKU:
K-57
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
K-57__1006
email_price:
no
Tags:
Customizations & Modifications
Label Option type:
rectangles
Net Price:
166.32
msrp_price:
no
Ship From:
75142
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Commercial Sink>>Commercial Sink Parts & Accessories
call_price:
no
map_price:
yes
Freight Class:
150
Packed By:
1 Each
add_to_cart:
no
MAP Price:
194.00
Manufacturer:
Advance Tabco
login_price:
yes
List Price:
432.00
Trigger BC Integration:
Y-6/2/2026_6:00PM
Filter_Manufacturer:
Advance Tabco
Primary Image:
Advance Tabco_K-57.png
specsheet:
Advance Tabco_K-57.pdf
warranty:
Advance Tabco_K-57_1.pdf
Sale Price:
174.60
732 Location Available:
0
Lead Time:
2 - 3 Weeks
Keyfeatures5:
Meets commercial sink parts requirements
Allow to show add to cart:
Login or Add to Cart to See Price
Keyfeatures4:
Reduces installation time for retrofits
Keyfeatures6:
Designed for professional food service
Keyfeatures:
Welded field joint ready for installation
Keyfeatures3:
Facilitates custom modifications
Keyfeatures2:
Compatible with Advance Tabco K-57 sinks
short_description:
Advance Tabco K-57 welded field joint offers a strong connection for on-site assembly, needing certified welders. It meets CSA guidelines and works with commercial sink systems for effective sanitary operations.
Adding to cart… The item has been added
Replace standard on-site seams with a precision-welded field joint designed for commercial sink systems, engineered to maintain fit and finish across custom fabrications. Installers achieve consistent alignment and robust junctions while preserving stainless steel integrity, minimizing site rework and reducing installation time. Fabricators and service teams benefit from a straightforward specification that integrates seamlessly with existing stainless workflows.
LongDescription#@#NA#@@#Cleaning Instructions#@#Disconnect power or gas to nearby equipment and clear the area. Remove debris and wipe weld joint with a cloth dampened in a mild detergent solution. Scrub remaining residue with a non-abrasive brush. Rinse surfaces with clean water and dry thoroughly to prevent corrosion. Inspect welds for cracks or gaps; repair by a certified welder if needed. Clean vents and surrounding areas regularly to reduce grease buildup, fire risk, and bacterial contamination.#@@#Additional Info#@#Advance Tabco K-57 Welded Field Joint offers a site-welded connection for commercial sinks, installed by certified welders for leak-free seams. Engineers specify it for custom setups; CSA-compatible materials ensure compliance and durability.#@@#General Info#@#Description #@# Replace standard on-site seams with a precision-welded field joint designed for commercial sink systems, engineered to maintain fit and finish across custom fabrications. Installers achieve consistent alignment and robust junctions while preserving stainless steel integrity, minimizing site rework and reducing installation time. Fabricators and service teams benefit from a straightforward specification that integrates seamlessly with existing stainless workflows. #@@# Weld Prepared Edges#@# Fabricators receive edges prepped for welding, ensuring uniform penetration and consistent fusion during field installation. Installers achieve predictable joint geometry that supports leak-free performance and simplifies final inspection processes. #@@# Field Weld Compatibility#@# The design accommodates on-site welding by certified trades, allowing technicians to adapt connections to existing piping and supports. Contractors maintain system rigidity and water containment when they weld according to local codes. #@@# Stainless Integration#@# The specification matches common stainless grades used in commercial sinks, enabling cohesive material behavior under thermal cycles and corrosion exposure. Maintenance teams observe fewer galvanic issues when welds occur between like materials, enhancing overall durability. #@@# Custom Fit Adaptation#@# Measurements allow for final trimming and alignment at the jobsite to match irregular floor and wall conditions, reducing the need for costly replacement parts. Project managers control fit tolerances during installation to meet finish specifications effectively. #@@# Service-Oriented Documentation#@# Provide clear installation notes and weld access requirements to streamline coordination between welding contractors and plumbing crews. Supervisors can reduce coordination errors by using concise guidance tailored to commercial kitchen schedules, ensuring smooth operations. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Advance Tabco K-57 Welded Field Joint periodically for weld integrity and corrosion; document visual findings and schedule repairs promptly. Remove debris and clean surfaces with mild detergent and warm water; rinse thoroughly and dry to prevent staining. Verify alignment and secure fasteners after field welding. Lubricate hinges and seals with food-grade lubricant. Train staff on inspection intervals and maintain service records for CSA and warranty compliance.