Skip to main content

AccuTemp E62083E150 6 Pans Countertop Convection Steamer Connected Evolution Boilerless - 208 Volts

AccuTemp

$12,598.85
(No reviews yet) Write a Review
SKU:
E62083E150
Weight:
231.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
E62083E150__1178
email_price:
no
Tags:
Steamer, Convection, Boilerless, Countertop
Label Option type:
rectangles
Net Price:
10336.78
msrp_price:
no
Ship From:
46774
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Cooking Equipments>>Steam Cooking Equipments>>Commercial Steamer
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 210-5907
Freight Class:
85
add_to_cart:
no
MAP Price:
12598.85
Manufacturer:
AccuTemp
login_price:
no
Product ID:
3c7f0e1b-0bce-de11-8d01-001ec95274b6
List Price:
22907.00
Taxonomy Weight:
231
Filter Type:
Convection Steamers
Other Available Options:
Electric
Filter_Power Type:
Electric
Filter_Steam Source:
Boilerless
Filter_Voltage:
208 Volts
Filter_Pan Capacity:
5 - 9 Pans
Filter_Type:
Convection Steamers
Oven Type:
Convection Steamer
Trigger BC Integration:
Y-6/19/2026_1:05PM
Primary Image:
E62083E150.png
specsheet:
AccuTemp_E62083E150.pdf
Sale Price:
12598.85
warranty:
AccuTemp_E62083E150_1.pdf
manual:
AccuTemp_E62083E150_2.pdf
Packed By:
1 Each
Filter_Style:
Countertop
NSF Certified:
Yes
Energy Efficiency:
ENERGY STAR
Operation:
Boilerless
Pan / Tray Size Capacity:
12" x 20" Pans
Made in USA:
Yes
ENERGY STAR®:
Yes
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
AccuTemp
Voltage:
208v
Filter_Made in America:
Yes
Power Type:
Electric
Pan Capacity:
6 Pans
Style:
Countertop
Item Type:
Convection Steamers
Filter_NSF Listed:
Yes
732 Location Available:
0
UL EPH Classified:
Yes
Real Weight:
231
Real Width:
27
Real Height:
33
Keyfeatures5:
15 kW, 208V, 3-Ph, NEMA 15-50P cord
Keyfeatures4:
Holds 12"x20"x2.5" pans for volume prep
Keyfeatures6:
ENERGY STAR, NSF, UL EPH compliant
Keyfeatures:
6 Pans boilerless convection steamer
Keyfeatures3:
Digital controls, water/drain plumbed
Keyfeatures2:
Steam Vector Technology for uniform cooking
short_description:
AccuTemp E62083E150 6-pan countertop convection steamer offers precise, boilerless steam cooking with Steam Vector Technology.
Lead Time:
2 - 3 Business Days
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
When service volume and steam quality matter, this countertop convection steamer delivers professional performance for foodservice operations. It operates without a boiler, uses Steam Vector Technology for uniform steam distribution, and supports six 12" x 20" pans for consistent output. Facilities managers will value the 15 kW, 208 volts, three-phase electrical specification and ENERGY STAR certification for efficiency.
LongDescription#@#NA#@@#Cleaning Instructions#@#Disconnect power and cool unit. Remove pans and wash with warm, soapy water; rinse and dry. Flush water line and open drain to clear deposits. Wipe chamber and gasket with non-abrasive cleaner; inspect seals and hinges. Clean exterior with mild detergent and soft cloth. Descale per manufacturer when mineral buildup appears. Clean vents and condenser area to maintain efficiency. Reconnect power only after unit is fully dry.#@@#Additional Info#@#AccuTemp E62083E150 countertop convection steamer uses steam vector tech for uniform cooking, operates boilerless on 208V, 15 kW, 3-Ph, with digital controls, plumbed water/drain, 5' cord, NEMA 15-50P, ENERGY STAR, NSF, UL listed.#@@#General Info#@#Description #@# When service volume and steam quality matter, this countertop convection steamer delivers professional performance for foodservice operations. It operates without a boiler, uses Steam Vector Technology for uniform steam distribution, and supports six 12" x 20" pans for consistent output. Facilities managers will value the 15 kW, 208 volts, three-phase electrical specification and ENERGY STAR certification for efficiency. #@@# Countertop Convection#@# Designed for standard prep counters, the unit fits kitchens needing a compact footprint and high throughput. Convection airflow reduces cycle times while preserving food texture and yield. #@@# Boilerless Operation#@# The boilerless design eliminates a steam boiler, reducing water use compared to traditional systems. Operators connect supply and drain plumbing directly; the unit includes a 5' cord with NEMA 15-50P for easy electrical setup. #@@# Steam Vector Technology#@# Steam Vector Technology ensures even steam distribution across all six pans, minimizing cold spots and delivering consistent results. Chefs can achieve uniform cooking for proteins, vegetables, or reheating prepared items. #@@# Digital Controls#@# Digital controls provide precise temperature and time management for repeatable production. Programmable settings reduce operator variability and support large-scale menu execution in restaurants, hospitals, and institutional kitchens. #@@# Six Pan Capacity#@# With capacity for six 12" x 20" x 2-1/2" pans, the steamer handles high-volume batches without stacking or rotation. This suits universities, schools, and large catering operations with continuous service needs. #@@# Service Resilience#@# The unit is certified by NSF, UL EPH, and CULUS, with domestic assembly in the USA. Warranty terms are unaffected by water quality, and no water filtration is required, simplifying maintenance for facilities teams. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser and steam nozzles weekly to prevent scale and maintain steam Vector performance. Flush water lines and drain connections monthly to remove sediment; follow local codes when disposing. Descale with manufacturer‑approved solution every 3–6 months depending on water hardness; sealing warranty allows varied water quality and removes need for filtration. Verify door gaskets and pan rails for wear; replace damaged parts immediately. Record service dates and hours of operation.