Skip to main content

AccuTemp ALTGSE-40-LP 40 Gal. Liquid Propane AccuTemp Edge Series Tilting Skillet - 100,000 BTU

AccuTemp

$29,371.10
(No reviews yet) Write a Review
SKU:
ALTGSE-40-LP
Weight:
625.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
ALTGSE-40__1178
other_types:
ALTGSE-40-LP$Liquid Propane#@#ALTGSE-40-NG$Natural Gas
Base:
Open Frame
Filter Type:
Skillets
Oven Type:
Tilting Skillet
Voltage:
120v
email_price:
no
Tags:
Tilting Skillet Braising Pan, Gas
Label Option type:
rectangles
Net Price:
24097.65
msrp_price:
no
Ship From:
46774
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Cooking Equipments>>Steam Cooking Equipments>>Tilt Skillets / Braising Pan
Other Available Options:
Liquid Propane
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 210-5907
add_to_cart:
no
MAP Price:
29371.10
Manufacturer:
AccuTemp
login_price:
no
List Price:
53402.00
Trigger BC Integration:
Y-6/19/2026_1:05PM
Capacity:
40 Gal.
Phase:
1-Ph
Hertz:
60
Filter_Power Type:
Liquid Propane
Filter_Capacity:
30 - 45 Gallons
Filter_Type:
Skillets
Primary Image:
AccuTemp_ALTGSE-40-LP.png
Sale Price:
29371.10
NSF Certified:
Yes
Filter_Manufacturer:
AccuTemp
Filter_Voltage:
120 Volts
specsheet:
AccuTemp_ALTGSE-40-LP.pdf
warranty:
AccuTemp_ALTGSE-40-LP_1.pdf
Tilt:
Manual
UL Certified:
Yes
Length:
47.5"
Taxonomy Weight:
625
Power Type:
Liquid Propane
Total BTU:
100,000 BTU
Filter_Total BTU:
100,000 - 120,000 BTU
Filter_Installation Type:
Floor Model
Item Type:
Skillets
Filter_NSF Listed:
Yes
Keyfeatures4:
304 stainless steel pan resists corrosion and warping
Keyfeatures:
40 Gal. propane capacity enables rapid cooking
Keyfeatures3:
Manual tilt with self-locking gear for safe transfer
Keyfeatures2:
100,000 BTU ensures high-temperature performance
short_description:
Engineered for high-demand kitchens, the AccuTemp ALTGSE-40-LP tilting skillet offers precise control and a 40-gallon capacity for large-batch cooking.
Real Width:
59.1
Real Height:
3
Lead Time:
2 - 3 Business Days
is free shipping:
Yes
PRO:
yes
Adding to cart… The item has been added
Built for continuous high-volume cooking, this commercial tilting skillet combines a 40-gallon capacity with a 100,000 BTU input to drive fast, consistent production without sacrificing process control. Operators gain precise temperature management via a thermostatic control and reliable ignition options, allowing repeatable results across large batches and varied preparations. Service teams will appreciate the open frame design and accessible components that simplify routine inspection and maintenance.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug or shut gas and power. Drain and cool pan to safe temperature. Scrape food residue, then clean with mild detergent and a soft cloth; avoid abrasive pads on 304 stainless. Rinse thoroughly and sanitize food-contact surfaces per CSA guidelines. Clean grease traps, vents, and exterior daily to reduce fire risk. Inspect seals and valves; clean coils and burners monthly to optimize efficiency and prevent failures. Dry completely before restoring gas and power.#@@#Additional Info#@#AccuTemp ALTGSE-40-LP tilting skillet has a 40 Gal. propane capacity and 100,000 BTU output, ideal for high-volume cooking. It features thermostatic controls, manual tilt, heavy-duty cover, stainless steel pan, and robust 625-pound construction.#@@#General Info#@#Description #@# Built for continuous high-volume cooking, this commercial tilting skillet combines a 40-gallon capacity with a 100,000 BTU input to drive fast, consistent production without sacrificing process control. Operators gain precise temperature management via a thermostatic control and reliable ignition options, allowing repeatable results across large batches and varied preparations. Service teams will appreciate the open frame design and accessible components that simplify routine inspection and maintenance. #@@# 40 Gallons#@# This pan holds 40 gallons, enabling large batch braising, steaming, or sautéing in a single cycle. Chefs reduce batch changeovers and maintain consistent output for high-traffic meal periods. #@@# High Heat Output#@# The unit delivers 100,000 BTU to accelerate heat-up and recovery for dense loads. Kitchens achieve faster cook times and stable temperatures during continuous operation. #@@# Liquid Propane#@# Designed for liquid propane operation, the power source supports installations where natural gas is unavailable. Facilities maintain fuel flexibility while matching site utility plans. #@@# Thermostatic Control#@# Built-in thermostatic control provides precise temperature regulation across the full range of the pan. Culinary staff reproduce menu items reliably and minimize waste from overcooking. #@@# Manual Tilt Mechanism#@# A self-locking worm gear with a manual tilt offers safe, controlled discharge of contents into receiving vessels. Teams reduce manual handling risk and speed transfer during peak service. #@@# Durable Construction#@# Constructed with 304 stainless steel and a clad pan body, the system resists corrosion and stands up to continuous use. Maintenance crews find surfaces easy to clean and compliant with sanitation protocols. #@@# Actuator Cover#@# The heavy-duty actuator-assisted cover includes a condensate drip shield and vent to control moisture and improve final product texture. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect burners weekly and remove debris to maintain consistent 100,000 BTU output. Drain and flush the 40 gallons capacity pan monthly to remove sediment; refill with potable water and run to operating temperature to sterilize. Lubricate the self-locking worm gear and tilt mechanism quarterly with food-grade lubricant; exercise the manual tilt to verify smooth operation. Verify seals and condensate drip shield after each shift and replace damaged components promptly.