Stop settling for inconsistent drain control. This thermostatic trap delivers reliable condensate management for commercial steam and hot water equipment while minimizing manual intervention and reducing downtime risk. Its compact 1/4in compression connections fit tight service spaces and allow straightforward integration with existing piping layouts.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch areas like menu covers, shakers, chair backs, and door handles with an EPA-approved disinfectant; follow label dwell time and use microfiber cloths. Clean tables, shelving, and booth crevices daily to remove crumbs and spills. Vacuum or sweep under shelves and booths, then mop with a neutral cleaner. Inspect and tighten fittings on seating weekly. Regular cleaning prevents contamination, supports health-code compliance, and deters pests.#@@#Additional Info#@#PartsTown CLE20559 thermostatic trap, 1/4" compression connection, offers temperature-responsive condensate drainage for kitchen steam equipment. It fits compact spaces, weighs 0.25 pounds, measures 2.15" by 1.95", and meets CSA standards.#@@#General Info#@#Description #@#
Stop settling for inconsistent drain control. This thermostatic trap delivers reliable condensate management for commercial steam and hot water equipment while minimizing manual intervention and reducing downtime risk. Its compact 1/4in compression connections fit tight service spaces and allow straightforward integration with existing piping layouts.
#@@# Thermostatic Trap#@#
This unit uses a thermostatic element that responds rapidly to temperature changes, ensuring condensate evacuates efficiently while retaining live steam. Rapid response reduces flash steam and prevents water hammer, improving system stability and thermal transfer.
#@@# Compression Connections#@#
The 1/4in compression fittings provide leak-resistant joins without soldering, enabling faster installation and maintenance. Technicians can fit or replace the trap using standard hand tools, decreasing labor time during scheduled service.
#@@# Compact Footprint#@#
At roughly 2.15 inches long and 1.95 inches high, the compact form factor suits confined headers and close-coupled coil assemblies. Designers can conserve cabinet space and route piping with minimal bends, preserving flow characteristics.
#@@# Lightweight Construction#@#
Weighing approximately 0.25 pounds, the trap imposes minimal load on fragile piping and supports. Installers gain handling advantages during overhead or remote mounting, streamlining field work and reducing strain.
#@@# Durability Features#@#
Manufactured for consistent operation in commercial environments, the trap employs materials and tolerances that withstand repeated thermal cycling. Service teams experience fewer premature failures and extended replacement intervals.
#@@# Compliance And Traceability#@#
The component carries manufacturer identification and part numbering for procurement and maintenance tracking, matching facility asset management practices established since 1998.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the thermostatic trap CLE20559 monthly to verify secure 1/4in compression connections and check for leaks. Use a torque wrench to tighten fittings to specifications and replace softened seals. Flush the line with potable water at low pressure to remove particulates, then open and close the device several times to ensure free movement. Descale internal components with a neutral pH solution when buildup exceeds 0.1 inches.