Skip to main content

Victory FSA-1D-S1-PT-HG-HC 26.5" W UltraSpec Series Freezer - 115 Volts

Victory

$14,611.35
(No reviews yet) Write a Review
SKU:
FSA-1D-S1-PT-HG-HC
Weight:
454.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
FSA-1D-S1-PT-HG-HC__1319
Compressor HP:
1/2
Door Style:
Half Door(s)
Door Type:
Glass
Filter Construction:
All Stainless Steel
Refrigeration:
Top Mounted
email_price:
no
Tags:
Freezer, Pass-Thru
Label Option type:
rectangles
Net Price:
12359.60
msrp_price:
no
Ship From:
15825
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Reach-In Refrigerators and Freezers>>Reach-In Freezers
call_price:
no
map_price:
yes
Freight Class:
150
Packed By:
1 Each
add_to_cart:
no
MAP Price:
14611.35
Manufacturer:
Victory
login_price:
no
List Price:
44479.00
Trigger BC Integration:
Y-1/6/2026_6:15PM
Made in USA:
Yes
Capacity:
23.7 Cu. Ft.
Taxonomy Weight:
454
Amps:
9.1
cULus Certified:
Yes
Phase:
1-Ph
Hertz:
60
Filter_Manufacturer:
Victory
Filter_Capacity:
11 - 31 Cubic Feet
Filter_Number of Doors:
4 Doors
Filter_Voltage:
115 Volts
Filter_Pass-Through:
Yes
Filter_Features:
LED Lighting
Filter_Width:
21 - 30 Inches
Filter_Refrigerant Type:
R-290
Filter_Compressor Location:
Top Mounted
Filter_Construction:
All Stainless Steel
Primary Image:
Victory_FSA-1D-S1-PT-HG-HC.png
specsheet:
Victory_FSA-1D-S1-PT-HG-HC.pdf
warranty:
Victory_FSA-1D-S1-PT-HG-HC_1.pdf
Sale Price:
14611.35
is free shipping:
Yes
Number of Doors:
4
Refrigerant Type:
R-290
Voltage:
115v
Nema Plug Type:
NEMA 5-15P
Filter_Door Type:
Glass
Filter_Hinge Location:
Left/Right
instructions:
Victory_FSA-1D-S1-PT-HG-HC_3.pdf
Keyfeatures5:
Top-mounted refrigeration with R-290
Keyfeatures4:
Glass half doors for quick inventory checks
Keyfeatures6:
Stainless steel exterior and aluminum interior
Keyfeatures:
26.5" W UltraSpec reach-in freezer, pass-thru design
Keyfeatures3:
All stainless steel for durability
Keyfeatures2:
23.7 Cu. Ft. storage capacity
short_description:
Built for continuous service, the Victory FSA-1D-S1-PT-HG-HC freezer offers 23.7 cu. ft. of volume in a 26.5" W footprint.
PRO:
yes
Filter_Pro:
yes
Construction:
All Stainless Steel
Filter_Sections:
1
UL EPH Classified:
Yes
Adding to cart… The item has been added
High-capacity cold storage designed for continuous service and precise temperature control. This one-section pass-thru freezer offers 23.7 Cu. Ft. of usable space within a compact 26.5-inch width, allowing for tight back-of-house footprints to accommodate full-size frozen inventories without compromise. Operators will appreciate the top-mounted refrigeration and glass half doors that provide easy access and visibility while maintaining consistent internal conditions.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and remove all product. Empty and defrost thoroughly. Mix a mild detergent with warm water (do not use bleach). Wipe interior surfaces, shelves, and gaskets with a soft cloth; rinse and dry completely. Clean condenser coils externally with a coil brush to improve efficiency and lower energy use. Inspect door seals for damage and replace if worn. Regular cleaning reduces bacteria, cuts fire risk from grease buildup, and prevents costly equipment failures.#@@#Additional Info#@#Victory's FSA-1D-S1-PT-HG-HC 26.5" UltraSpec freezer offers 23.7 cu. ft.#@@#General Info#@#Description #@# High-capacity cold storage designed for continuous service and precise temperature control. This one-section pass-thru freezer offers 23.7 Cu. Ft. of usable space within a compact 26.5-inch width, allowing for tight back-of-house footprints to accommodate full-size frozen inventories without compromise. Operators will appreciate the top-mounted refrigeration and glass half doors that provide easy access and visibility while maintaining consistent internal conditions. #@@# Top-Mounted Refrigeration#@# Top-mounted refrigeration concentrates service access and simplifies maintenance, keeping mechanical components elevated from floor hazards. This configuration supports a 1/2 HP compressor and operates on a 115-volt electrical supply, delivering reliable cooling power and straightforward serviceability. #@@# Glass Half Doors#@# Glass half doors enhance inventory visibility and reduce door open time, improving thermal stability and minimizing product temperature fluctuations. Staff can quickly identify stock without prolonged exposure to ambient air, which reduces the recovery load on the refrigeration system. #@@# All Stainless Steel#@# Constructed entirely of stainless steel, this unit resists corrosion and withstands frequent cleaning cycles typical in commercial kitchens. Maintenance crews will find the surfaces durable and compliant with standard sanitizing protocols, supporting compliance efforts effectively. #@@# Pass-Thru Configuration#@# The pass-thru configuration allows staff to stage and transfer frozen goods between kitchen and service areas without backtracking, enhancing workflow and minimizing bottlenecks. The left-right hinge option supports flexible placement and traffic patterns in tight spaces. #@@# R-290 Refrigerant System#@# The R-290 refrigerant system offers efficient heat transfer and a lower global warming potential compared to older refrigerants, enabling energy-efficient operation. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#Upon confirmation of completed payment, Culinary Depot will ship/deliver the Victory FSA-1D-S1-PT-HG-HC UltraSpec™ Series Freezer.#@@#Maintenance Guide#@#Inspect condenser coils weekly and remove debris to maintain heat transfer efficiency. Check door gaskets for cracks and replace when compression fails. Calibrate thermostat monthly and record setpoints to ensure stable storage temperatures. Defrost per manufacturer schedule; remove ice buildup to restore airflow. Lubricate hinges quarterly and tighten fasteners. Verify electrical connections and NEMA 5-15P plug integrity before each service interval.