Stop trading reliability for performance. This remote condensing unit delivers consistent refrigeration capacity while minimizing its footprint and maintenance demands, allowing operations to maintain ice production and cooling loads without interruption. Designed for commercial installations, it integrates seamlessly with existing systems using R-404A refrigerant and standard 208/230 volts electrical service.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the RC25 and lock out power at 208/230v before service. Remove debris from fins with a soft brush; wash coils with a low-pressure water spray and approved coil cleaner. Inspect R-404A connections for leaks and tighten fittings; replace deteriorated gaskets. Clear condensate drains and verify pump operation. Measure amp draw and record values. Clean fan blades and motor vents to prevent grease buildup and fire risk. Perform monthly checks to maintain efficiency and pass CSA inspections.#@@#Additional Info#@#Taylor Company RC25 Remote Condensing Unit runs on 208/230 volts with R-404A refrigerant and cULus certification. It weighs 200 pounds and supports foodservice and hospitality with reliable performance and durable components.#@@#General Info#@#Description #@#
Stop trading reliability for performance. This remote condensing unit delivers consistent refrigeration capacity while minimizing its footprint and maintenance demands, allowing operations to maintain ice production and cooling loads without interruption. Designed for commercial installations, it integrates seamlessly with existing systems using R-404A refrigerant and standard 208/230 volts electrical service.
#@@# Compressor Capacity#@#
This unit utilizes a purpose-sized compressor rated for R-404A, supporting steady heat rejection and sustained load handling. Installers will find that the output aligns perfectly with medium commercial ice machines and cold rooms, enabling continuous operation even in high-demand environments.
#@@# Compact Footprint#@#
Engineers designed the chassis to occupy minimal space, with a depth of 24.25 inches and a width of approximately 24.84 inches. This design allows for rooftop or exterior wall mounting where space constraints exist, helping facilities conserve mechanical room area and simplifying placement next to existing service lines.
#@@# Certified Safety Compliance#@#
The assembly carries cULus certification, meeting recognized safety and electrical standards for commercial equipment in North America. Maintenance teams will find the documentation sufficient for code inspections and insurer reviews, ensuring compliance and safety.
#@@# Electrical Compatibility#@#
The condensing unit accepts 208/230 volts input, matching common commercial three-phase or single-phase supplies in institutional settings. Electricians can easily integrate the unit into typical service panels without extensive rewiring, streamlining installation.
#@@# Serviceability Design#@#
Access panels and standard component layouts significantly reduce service time for routine tasks such as filter checks, fan motor replacement, and refrigerant circuit diagnostics.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser coils monthly and remove debris to maintain heat transfer efficiency. Use a soft brush and low-pressure air; avoid bent fins. Flush refrigerant lines annually and verify R-404A charge per manufacturer specifications. Lubricate fan motor bearings semiannually and tighten electrical connections at 208/230 volts to prevent voltage drop. Replace aged gaskets and check mounting brackets for corrosion. Record service dates and maintain CSA documentation for compliance.