Skip to main content

T&S Brass B-0975-GH Vacuum Breaker dual check valve

T&S Brass

$319.84
(No reviews yet) Write a Review
SKU:
B-0975-GH
Weight:
1.20 LBS
Shipping:
Calculated at Checkout
SKU Number:
B-0975-GH__1284
Valve:
Dual check valve
email_price:
no
Tags:
Vacuum Breaker Assembly
Label Option type:
rectangles
Net Price:
255.87
msrp_price:
no
Product Taxonomy:
CulinaryDepot>>Restaurant Equipment>>Restaurant Faucet and Plumbing>>Faucet, Sink, & Drain Accessories>>Faucet Parts and Accessories>>Breakers, Valves & Preventers
call_price:
yes
map_price:
Yes
Freight Class:
77.5
add_to_cart:
yes
MAP Price:
319.84
Manufacturer:
T&S Brass
login_price:
no
Product ID:
6bee8def-6a40-4a04-b531-b6e418d26375
List Price:
536.40
Trigger BC Integration:
Y-1/6/2026_6:15PM
Taxonomy Weight:
1.2
Primary Image:
B-0975-GH.jpg
Sale Price:
319.84
specsheet:
T&S Brass_B-0975-GH.pdf
Filter_Pro:
yes
PRO:
yes
NSF Certified:
Yes
Filter_NSF Listed:
Yes
Filter Type:
Vacuum Breakers
Filter_Manufacturer:
T&S Brass
Filter_Type:
Vacuum Breakers
Keyfeatures5:
1.2 pounds for easy installation
Keyfeatures4:
Compact form fits standard faucet assemblies
Keyfeatures6:
CSA-compatible material
Keyfeatures:
Lead-free construction for potable water
Keyfeatures3:
Meets industry standards with NSF Certified performance
Keyfeatures2:
Dual check valve design prevents backflow
short_description:
T&S Brass B-0975-GH vacuum breaker dual check valve installs inline to protect potable water systems from backflow and maintain pressure.
Lead Time:
2 - 4 Business Days
Adding to cart… The item has been added
Built for high-demand plumbing applications, this vacuum breaker ensures reliable backflow prevention while fitting compact installations. Engineers designed the dual check valve to provide consistent protection against contamination and simplify maintenance in commercial kitchens, bars, and institutional settings. Facility managers gain a durable component that integrates with standard faucet and sink accessories to support code compliance and operational continuity.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug affected equipment and remove debris. Mix mild detergent with warm water and scrub food-contact surfaces with a nonabrasive cloth. Rinse thoroughly and air-dry or towel-dry. Clean vents, oven interiors, and grease traps weekly to prevent fire hazards. Inspect seals, coils, and moving parts; replace worn components. Follow CSA guidelines for certified devices like the T&S Brass B-0975-GH dual check valve. Regular cleaning prevents contamination, breakdowns, and inspection failures.#@@#Additional Info#@#T&S Brass B-0975-GH vacuum breaker features a dual check valve to prevent backflow in plumbing. CSA-certified, it supports continuous operation, and stainless components resist corrosion.#@@#General Info#@#Description #@# Built for high-demand plumbing applications, this vacuum breaker ensures reliable backflow prevention while fitting compact installations. Engineers designed the dual check valve to provide consistent protection against contamination and simplify maintenance in commercial kitchens, bars, and institutional settings. Facility managers gain a durable component that integrates with standard faucet and sink accessories to support code compliance and operational continuity. #@@# Dual Check Valve#@# Engineers configured the unit as a dual check valve to provide redundant sealing against backflow. Technicians can expect continuous prevention of cross-contamination under typical pressure conditions, reducing the risk of health code violations. #@@# Compact Installation#@# Designers sized the assembly for tight spaces, allowing installers to mount it near faucets and supply lines without extensive rerouting. Plumbers will complete retrofits faster and minimize service interruptions in high-traffic areas. #@@# Certified Performance#@# Manufacturers validated the component with CSA certification, offering documented compliance for municipal and institutional projects. Specification writers receive reliable certification data to support procurement and inspection processes. #@@# Serviceable Construction#@# Technicians access internal parts through a removable housing that reduces downtime during maintenance. Service crews perform inspections and part replacements with standard tools, lowering labor time and expense. #@@# Corrosion Resistance#@# The design uses materials selected to withstand regular exposure to water and cleaning agents, preserving sealing surfaces and valve function. Maintenance teams observe longer intervals between replacements, improving the total cost of ownership. #@@# Precise Weight and Fit#@# Specification lists a unit weight of 1.2 pounds to help planners calculate load and mounting requirements for fixtures and racks. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the T&S Brass B-0975-GH Vacuum Breaker dual check valve weekly for damage and corrosion. Use a soft brush and mild detergent to clean; rinse with potable water and dry thoroughly. Ensure the CSA certification label is legible. Cycle the valve monthly by isolating the line, disassembling per instructions, and replacing worn seals with compatible parts. Measure torque on fasteners to specifications. Flush lines quarterly at recommended flow rates to prevent buildup.