Stop compromising system reliability for speed. This compact water hammer arrestor prevents damaging pressure spikes in commercial dishwashing lines and protects pumps, valves, and fittings during rapid shutoff events. Designed for high-frequency institutional use, the unit installs inline on 1/2 inch supply runs to reduce maintenance downtime and extend equipment life.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug equipment and drain water lines before you start. Remove the Jackson WWS 1/2" water hammer arrestor following manufacturer torque specs. Mix mild detergent with warm water (use gallons or liters as needed) and wipe nearby pipes and fittings with a soft cloth. Inspect for scaling and replace seals showing wear. Clean vents and strainers to prevent grease buildup. Run water to purge air and verify arrestor function. Document maintenance date and CSA compliance where required.#@@#Additional Info#@#Jackson WWS 05700-002-64-67 1/2" Water Hammer Arrestor absorbs pressure spikes in dishwashing lines, fits 1/2" connections, weighs 48 pounds, and measures 37.63 x 19.63 x 2.27; CSA-compliant for commercial kitchens since 1998.#@@#General Info#@#Description #@#
Stop compromising system reliability for speed. This compact water hammer arrestor prevents damaging pressure spikes in commercial dishwashing lines and protects pumps, valves, and fittings during rapid shutoff events. Designed for high-frequency institutional use, the unit installs inline on 1/2 inch supply runs to reduce maintenance downtime and extend equipment life.
#@@# Flow Connection#@#
Install directly on 1/2 inch inlet lines to absorb hydraulic shock at the point of occurrence. Engineers specify the size to match common dishwasher supply fittings, ensuring proper damping without restricting flow.
#@@# Compact Dimensions#@#
Measuring 2.27 inches in height, 37.63 inches in width, and 19.63 inches in depth, this unit allows for straightforward placement in confined service cabinets. Facility teams gain flexibility when routing piping and mounting arrestors near dish machines and booster pumps.
#@@# Robust Construction#@#
Manufacturers build the device to withstand repeated pressure oscillations in commercial environments. Technicians will appreciate the solid assembly that limits fatigue and reduces the frequency of part replacements.
#@@# Maintenance Simplicity#@#
Routine inspections require minimal disassembly thanks to an accessible configuration and standard fittings. Service crews can minimize downtime through quick visual checks and snap-in replacements when necessary.
#@@# Weight And Handling#@#
Weighing 48 pounds, the component balances durability with manageable handling for two-person installations. Onsite installers can avoid special lifting equipment while maintaining safe ergonomic practices.
#@@# Compliance And Compatibility#@#
Align the unit with industry mechanical parts standards and common dishwasher accessory requirements for retrofit projects. Planners can integrate the arrestor into existing systems without altering pump or valve specifications.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Use the Jackson WWS 1/2" water hammer arrestor per manufacturer guidelines and inspect fittings weekly for leaks. Flush supply lines monthly to remove debris and verify arrestor orientation. Tighten connections to specified torque values and apply thread sealant on NPT joints. Replace unit if weight changes or visible damage appears. Record maintenance actions in logs and schedule annual pressure tests to confirm effective shock absorption.