Stop compromising on thermal control or workflow capacity. This self-contained indoor walk-in freezer delivers consistent low-temperature performance while simplifying installation and maintenance for high-demand food service operations. Owners and facilities managers gain predictable energy use, robust load ratings, and factory-tested refrigeration that integrates directly with existing kitchens.
LongDescription#@#Dade Engineering constructs our 8'x8'x7.7" self-contained indoor walk-in freezer with floor walk-ins using pre-fabricated, meticulously engineered modular panels designed for efficient and precise on-site assembly, adhering to the comprehensive construction specifications outlined in the Dade Coolers® Architectural Specifications and General Design Information guide. These panels and doors are intricately designed and certified to meet the stringent requirements for walk-in cooler and freezer applications as stipulated by the DOE. The insulation consists of 4-inch thick rigid polyurethane, expertly poured in place to ensure optimal thermal performance. The R-values for these 4-inch panels are as follows: Cooler walls, ceilings, and doors: R-25; Freezer walls, ceilings, and doors: R-32; Freezer floors: R-28. The inner and outer surfaces of the walk-in coolers and freezers are adorned with 26-gauge acrylic-coated stucco galvanized steel finishing, while the interior floor boasts textured aluminum with a .080 thickness. These floor panels are engineered to provide sturdy support for a uniformly distributed load of up to 700 lbs. per square foot. Standard walk-ins are equipped with a single flush-mount self-closing entrance door, measuring 36" x 78". The energy consumption for these doors is as follows: Coolers: 2.77 kWh/day; Freezers: 7.79 kWh/day. These entrance doors encompass various features, including adjustable backing plates for on-site hinge adjustments, two spring-loaded cam-lift hinges, hydraulic door closures, deadbolt-locking handles, pre-wired compact fluorescent vapor-proof light fixtures, interior safety releases, mounted dial thermometers, magnetic gaskets along the top and both sides, adjustable double vinyl wiper gaskets along the bottom, and drip guards designed for outdoor models.The self-contained refrigeration system comprises dedicated outdoor condensing units that meet the DOE's stipulated minimum AWEF rating requirement of 7.61 (Btu/W-h) for medium temperature applications. The refrigeration systems consist of a condensing unit and evaporator coil, both expertly assembled within a mill-finish aluminum housing. Each system arrives fully wired, piped, evacuated, optimally charged, and subjected to rigorous run-testing. These systems are primed for mounting atop a Dade Coolers® walk-in cooler or freezer and can be tailored for compartments measuring up to 13'6" in length. Some indoor models come equipped with a power cord, facilitating direct plug-in to a receptacle. Furthermore, the systems incorporate a factory-mounted diffuser, complemented by separately provided trim pieces for a polished finish inside the box. The evaporator grille is adeptly designed for flush or recessed installation within a 4-inch thick ceiling panel. Systems designated for medium temperature applications employ air defrost, while low-temperature models feature electric defrost. All units are furnished with R-404A refrigerant and are engineered to operate efficiently in ambient temperatures reaching up to 100°F. Outdoor walk-in systems are also outfitted with a crankcase heater, drainline heater, headmaster, and weather hood.#@@#Cleaning Instructions#@#Unplug power and empty the freezer. Remove shelves and sweep floor. Mix mild detergent with warm water (use gallons or liters as needed) and wipe all interior panels with a soft cloth. Clean condenser coils with a brush and vacuum to improve efficiency. Defrost per manufacturer instructions and dry surfaces thoroughly. Inspect door gaskets and hinges; replace worn parts. Reconnect power only after unit is completely dry to prevent electrical hazards.#@@#Additional Info#@#Dade Engineering's FI-887.7-SC indoor walk-in freezer measures 92.4" H x 96" W x 96" D. It features 4" rigid polyurethane panels, R-32 walls/ceiling, R-28 floor, and a 36" x 78" self-closing door.#@@#General Info#@#Description #@#
Stop compromising on thermal control or workflow capacity. This self-contained indoor walk-in freezer delivers consistent low-temperature performance while simplifying installation and maintenance for high-demand food service operations. Owners and facilities managers gain predictable energy use, robust load ratings, and factory-tested refrigeration that integrates directly with existing kitchens.
#@@# Insulated Paneling#@#
Four-inch rigid polyurethane panels provide targeted thermal resistance and structural integrity. Engineers specify R-32 for walls, ceilings, and doors, and R-28 for floors, ensuring stable 0°F operation and reduced runtime for the refrigeration system.
#@@# Floor Load Capacity#@#
Textured .080 aluminum floor panels withstand uniform loads up to 700 pounds per square foot, enabling pallet staging and heavy equipment placement. Designers and operators can configure storage layouts without compromising floor performance.
#@@# Self-Contained Refrigeration#@#
Factory-mounted condensing units pair with evaporator coils inside mill-finish aluminum housings and ship fully wired, piped, evacuated, charged, and run-tested. Technicians receive a ready-to-mount system that minimizes onsite commissioning time for compartments up to 13 feet 6 inches.
#@@# Door Components#@#
A single flush-mount self-closing swing door measures 36 inches by 78 inches and includes hydraulic closure, deadbolt lock, interior safety release, and mounted dial thermometer. Service staff benefit from magnetic gaskets and adjustable vinyl wipers that reduce air infiltration and simplify door adjustment.
#@@# Energy And Defrost Controls#@#
Medium-temperature systems meet a minimum AWEF of 7.61 and use air defrost, while low-temperature versions use electric defrost; all use R-448A refrigerant and operate effectively up to 100°F ambient. Facility managers receive documented kWh consumption for doors and a refrigeration platform designed for predictable energy budgeting.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Perform weekly inspections to verify gasket integrity, hinge function, and door alignment; replace damaged gaskets and adjust backing plates for consistent seals. Clean condenser coils monthly to prevent airflow restriction and reduce compressor load. Sanitize surfaces with mild detergent and potable water; rinse and dry shelves thoroughly. Defrost per manufacturer intervals, clear drain lines, and periodically verify refrigerant pressures and electrical connections.