Handle extreme cold storage demands with a durable, factory-engineered walk-in freezer that combines robust thermal performance and ready-to-run refrigeration. This unit features thick, poured-in-place insulation, engineered panel assembly, and a self-contained condensing system that ships fully precharged and tested for rapid installation. Facility managers receive predictable energy metrics and a modular design that fits indoor operations while supporting heavy use loads.
LongDescription#@#Dade Engineering constructs our 6'x6'x7.7" self-contained indoor walk-in freezer with floor walk-ins using pre-fabricated, meticulously engineered modular panels designed for efficient and precise on-site assembly, adhering to the comprehensive construction specifications outlined in the Dade Coolers® Architectural Specifications and General Design Information guide. These panels and doors are intricately designed and certified to meet the stringent requirements for walk-in cooler and freezer applications as stipulated by the DOE. The insulation consists of 4-inch thick rigid polyurethane, expertly poured in place to ensure optimal thermal performance. The R-values for these 4-inch panels are as follows: Cooler walls, ceilings, and doors: R-25; Freezer walls, ceilings, and doors: R-32; Freezer floors: R-28. The inner and outer surfaces of the walk-in coolers and freezers are adorned with 26-gauge acrylic-coated stucco galvanized steel finishing, while the interior floor boasts textured aluminum with a .080 thickness. These floor panels are engineered to provide sturdy support for a uniformly distributed load of up to 700 lbs. per square foot. Standard walk-ins are equipped with a single flush-mount self-closing entrance door, measuring 36" x 78". The energy consumption for these doors is as follows: Coolers: 2.77 kWh/day; Freezers: 7.79 kWh/day. These entrance doors encompass various features, including adjustable backing plates for on-site hinge adjustments, two spring-loaded cam-lift hinges, hydraulic door closures, deadbolt-locking handles, pre-wired compact fluorescent vapor-proof light fixtures, interior safety releases, mounted dial thermometers, magnetic gaskets along the top and both sides, adjustable double vinyl wiper gaskets along the bottom, and drip guards designed for outdoor models.The self-contained refrigeration system comprises dedicated outdoor condensing units that meet the DOE's stipulated minimum AWEF rating requirement of 7.61 (Btu/W-h) for medium temperature applications. The refrigeration systems consist of a condensing unit and evaporator coil, both expertly assembled within a mill-finish aluminum housing. Each system arrives fully wired, piped, evacuated, optimally charged, and subjected to rigorous run-testing. These systems are primed for mounting atop a Dade Coolers® walk-in cooler or freezer and can be tailored for compartments measuring up to 13'6" in length. Some indoor models come equipped with a power cord, facilitating direct plug-in to a receptacle. Furthermore, the systems incorporate a factory-mounted diffuser, complemented by separately provided trim pieces for a polished finish inside the box. The evaporator grille is adeptly designed for flush or recessed installation within a 4-inch thick ceiling panel. Systems designated for medium temperature applications employ air defrost, while low-temperature models feature electric defrost. All units are furnished with R-404A refrigerant and are engineered to operate efficiently in ambient temperatures reaching up to 100°F. Outdoor walk-in systems are also outfitted with a crankcase heater, drainline heater, headmaster, and weather hood.#@@#Cleaning Instructions#@#Unplug power and remove contents. Scrub interior panels and floor with a mild detergent solution; rinse and dry. Clean door gaskets and hinges; inspect seals and adjust hardware. Degrease condensers and coils; vacuum debris to improve efficiency. Defrost per manufacturer instructions and clear drain lines. Sanitize food-contact surfaces with an approved agent and air dry. Log cleaning dates to support CSA and inspection compliance.#@@#Additional Info#@#Dade Engineering’s FI-667.7-SC walk-in freezer is 92.4" H x 72" W x 72" D. It uses 4" rigid polyurethane panels (R-32 walls/ceilings/doors, R-28 floor) with 26-gauge steel surfaces and aluminum floor rated for 700 lbs/sq ft.#@@#General Info#@#Description #@#
Handle extreme cold storage demands with a durable, factory-engineered walk-in freezer that combines robust thermal performance and ready-to-run refrigeration. This unit features thick, poured-in-place insulation, engineered panel assembly, and a self-contained condensing system that ships fully precharged and tested for rapid installation. Facility managers receive predictable energy metrics and a modular design that fits indoor operations while supporting heavy use loads.
#@@# Rigid Insulation#@#
Four-inch rigid polyurethane fills each panel to deliver consistent thermal resistance across the envelope. Designers specified R-32 for freezer walls, ceilings, and doors, and R-28 for floors, yielding predictable heat gain control and reduced run time for refrigeration equipment.
#@@# Certified Panel Construction#@#
Manufactured modular panels arrive pre-fabricated for on-site assembly according to factory architectural specifications. Installers benefit from precise fit, factory tolerances, and stamped compliance with DOE walk-in cooler and freezer requirements.
#@@# Load Rated Flooring#@#
Textured aluminum floor panels with 0.080 thickness support uniform loads up to 700 pounds per square foot. Kitchen planners can stage loaded racks and palletized products without concern for localized floor failure.
#@@# Self-Contained Refrigeration#@#
The system includes a condensing unit and evaporator coil assembled in mill-finish aluminum housing, shipped fully wired, piped, evacuated, and optimally charged with R-448A refrigerant. Engineers receive equipment that meets a minimum AWEF of 7.61 for medium temperature applications and functions in ambient conditions up to 100°F.
#@@# Door Hardware Package#@#
A flush-mount self-closing swing door includes two spring-loaded cam-lift hinges, hydraulic closure, deadbolt locking handle, interior safety release, and magnetic and vinyl gasket sealing.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect door gaskets weekly and replace sections showing cracks or compression to maintain thermal integrity. Clean condenser coil monthly with a soft brush and low-pressure air to preserve heat transfer. Drain defrost pans and verify drainline heater operation quarterly to prevent ice build-up. Level unit and confirm floor fasteners remain torque-specified to avoid structural stress. Log temperatures daily and calibrate thermostat annually to ensure consistent 0°F performance.