Skip to main content

Dade Engineering CO-8147.7-SC 92.4" H x 96" W x 168" D Self-Contained Outdoor Walk-In Cooler With Floor - 208/230 Volts

Dade Engineering

$21,751.00
(No reviews yet) Write a Review
SKU:
CO-8147.7-SC
Weight:
2,320.00 LBS
Shipping:
Calculated at Checkout
Door Style:
Swing
Floor:
With Floor
Gauge:
26 Gauge
Refrigerant Type:
R-448A
Refrigeration Type:
Self-Contained
Temperature Range:
35°F
email_price:
No
Tags:
Walk-In Cooler
Label Option type:
rectangles
Net Price:
15597
msrp_price:
No
Product Taxonomy:
CulinaryDepot>>Commercial Refrigerator>>Walk-In Refrigeration>>Walk-In Coolers / Refrigerator
call_price:
No
map_price:
Yes
Packed By:
1 Each
MAP Price:
21751
Manufacturer:
Dade Engineering
login_price:
No
Trigger BC Integration:
Y-1/13/2026_6:00PM
Taxonomy Weight:
2320
Phase:
1-Ph
Hertz:
60
Filter_Manufacturer:
Dade Engineering
Filter_Voltage:
208/230 Volts
Filter_Depth:
151 - 200 Inches
Filter_Width:
51 - 100 Inches
Filter_Usage:
Outdoor
Filter_Height:
51 - 100 Inches
Filter_Refrigeration Type:
Self-Contained
Filter_Refrigerant Type:
R-448A
Primary Image:
Dade Engineering_CO-8147.7-SC.jpg
Sale Price:
21751
Voltage:
208/230v
Keyfeatures5:
Outdoor-ready with crankcase and drainline heaters
Keyfeatures4:
Self-contained condensing with AWEF 7.61
Keyfeatures6:
36"
Keyfeatures:
4" thick rigid polyurethane insulation R-25
Keyfeatures3:
Textured .080 aluminum floor supports 700 lbs/sq ft
Keyfeatures2:
26-gauge acrylic-coated stucco galvanized steel
short_description:
Engineers designed the CO-8147.7-SC outdoor cooler with 4" polyurethane panels and 26-gauge acrylic-coated galvanized steel for durability.
Adding to cart… The item has been added
Stop sacrificing reliability for outdoor installation readiness. This self-contained outdoor walk-in cooler combines durable construction with precise thermal control to support high-volume kitchen operations and strict food safety standards. Designed for prefab panel assembly and rugged outdoor exposure, the unit maintains consistent 35°F performance while minimizing energy use through optimized insulation and refrigeration components.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug the unit and remove all contents. Mix mild detergent with warm water (use gallons or liters as needed) and scrub interior panels, floor, door gaskets, and condenser access with a soft brush. Rinse and dry surfaces thoroughly. Vacuum condenser coils and clean fins to improve efficiency. Inspect seals and hinges; replace worn parts. Clean vents, drip pans, and evaporator grilles to prevent grease buildup and fire risk. Record cleaning dates to meet CSA and inspection standards.#@@#Additional Info#@#Dade Engineering's CO-8147.7-SC outdoor walk-in cooler measures 92.4" H x 96" W x 168" D, using 208/230 volts.#@@#General Info#@#Description #@# Stop sacrificing reliability for outdoor installation readiness. This self-contained outdoor walk-in cooler combines durable construction with precise thermal control to support high-volume kitchen operations and strict food safety standards. Designed for prefab panel assembly and rugged outdoor exposure, the unit maintains consistent 35°F performance while minimizing energy use through optimized insulation and refrigeration components. #@@# Wall And Ceiling Insulation#@# The 4-inch rigid polyurethane panels deliver an R-25 rating for cooler walls, ceilings, and doors, ensuring controlled internal temperatures and reduced compressor cycling. Installers benefit from a prefabricated, modular panel design that simplifies on-site assembly and maintains uniform thermal performance across the envelope. #@@# Floor Load Capacity#@# The textured aluminum floor, with a thickness of .080, supports a uniformly distributed load of up to 700 pounds per square foot to accommodate heavy storage racks and frequent foot traffic. Facility managers receive a durable surface that resists corrosion and simplifies routine cleaning while preserving structural integrity. #@@# Outdoor Door Assembly#@# The flush-mount self-closing swing door includes hydraulic closures, deadbolt locking handles, an interior safety release, magnetic gaskets at the top and sides, and adjustable double vinyl wiper gaskets at the bottom to prevent airflow infiltration. Operators gain reliable sealing and user safety features that reduce energy loss and maintain internal setpoints during high-traffic periods. #@@# Self-Contained Refrigeration#@# The system ships fully wired, piped, evacuated, charged, and run-tested with a dedicated outdoor condensing unit and evaporator in a mill-finish aluminum housing. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect condenser coils weekly and remove debris to maintain thermal transfer. Clean interior panels and textured aluminum floor with a neutral detergent and low-abrasion cloth; rinse and dry thoroughly to prevent corrosion. Verify door magnetic gasket integrity and adjust backing plates or replace gaskets when leakage or wear appears. Monitor refrigerant pressures and defrost cycles monthly; tighten electrical connections quarterly. Document all service actions for CSA compliance.