Stop compromising durability for convenience. This walk-in cooler delivers industrial-grade thermal performance and field-ready components to support continuous cold storage in outdoor installations, ensuring consistent 35°F conditions for foodservice operations that demand reliability and predictable energy use. Designed for straightforward on-site assembly, this unit provides quantified insulation, tested refrigeration, and a traffic-ready floor system that supports heavy loads and frequent access.
LongDescription#@#NA#@@#Cleaning Instructions#@#Unplug power and empty the cooler. Remove shelving and sweep loose debris. Mix mild detergent with warm water (use gallons or liters as needed) and scrub panels, door gaskets, and floor with a non-abrasive cloth. Rinse thoroughly and dry all surfaces before restoring power. Clean condenser coils monthly to lower energy use and prevent breakdowns. Inspect gaskets and hinges; replace worn parts to maintain food safety and pass CSA inspections.#@@#Additional Info#@#Dade Engineering's CO-6107.7-SC outdoor cooler is 92.4" H x 72" W x 120" D, offers 450 cu. ft. capacity, and uses 4" rigid polyurethane panels. It features a top-mounted refrigeration system, meets DOE AWEF 7.61, and operates on 208/230 volts.#@@#General Info#@#Description #@#
Stop compromising durability for convenience. This walk-in cooler delivers industrial-grade thermal performance and field-ready components to support continuous cold storage in outdoor installations, ensuring consistent 35°F conditions for foodservice operations that demand reliability and predictable energy use. Designed for straightforward on-site assembly, this unit provides quantified insulation, tested refrigeration, and a traffic-ready floor system that supports heavy loads and frequent access.
#@@# Insulated Panel Construction#@#
High-density 4-inch rigid polyurethane panels produce an R-25 rating for cooler walls, ceilings, and doors, yielding controlled thermal retention and reduced compressor runtime. Engineers cast panels to exact tolerances to simplify alignment during field assembly and to maintain consistent surface finishes that resist weather exposure.
#@@# Load Rated Flooring#@#
Textured aluminum floor panels at .080 thickness support uniformly distributed loads up to 700 pounds per square foot, enabling safe storage of pallets, racks, and mobile carts. Design choices minimize slippage and allow maintenance staff to maneuver equipment without compromising floor integrity.
#@@# Weather-Ready Door Assembly#@#
A single flush-mount self-closing swing door sized 36 inches by 78 inches integrates adjustable backing plates, hydraulic closures, spring-loaded cam-lift hinges, and deadbolt locking hardware for secure, serviceable access. Magnetic and vinyl wiper gaskets combined with drip guards and interior safety release features preserve thermal integrity while supporting outdoor exposure.
#@@# Self-Contained Refrigeration#@#
The factory-tested condensing unit and evaporator coil ship fully wired, piped, evacuated, and charged to operate at medium temperature loads using R-448A refrigerant. Systems achieve a minimum AWEF of 7.61 Btu per W-h, run-tested for ambient operation up to 100°F, and include crankcase and drainline heaters for outdoor reliability.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect door gaskets and hinges monthly; replace worn seals to maintain temperature control and prevent air infiltration. Clean condenser coils and evaporator grilles every three months with a brush and low-pressure air for heat transfer efficiency. Sanitize interior panels and aluminum floors with a neutral detergent; rinse and dry to avoid corrosion. Verify refrigerant lines and electrical connections semiannually; tighten fittings and test compressor amperage to ensure performance.