Stop allowing uncontrolled air and contaminants to compromise cleanliness at entry points. This low-profile air curtain delivers targeted, continuous airflow to protect interior zones, maintain sanitation, and minimize infiltration across doorways up to 7 feet high. Engineers designed the unit for both interior and exterior mounting, featuring a single 1.5 horsepower motor and a 120 volts 1-Ph electrical configuration to seamlessly integrate with existing facility systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior surfaces and high-touch zones (menu covers, chair backs, handles, salt shakers) with a detergent solution, then rinse and apply an EPA-registered sanitizer per label. Clean under shelves and booth crevices to remove food residue and deter pests. Inspect and tighten fasteners on fixtures after cleaning. Regular cleaning prevents cross-contamination, supports health-code compliance, and preserves furnishings' finish and service life.#@@#Additional Info#@#Berner's SLC07-1048A air curtain provides airflow for doors up to 7 Ft. It features one 1/5 HP motor, 120 volts, and is designed for interior or exterior use. UL and cULus certified, it has a 48.06" width, 8.5" height, and weighs 54 pounds.#@@#General Info#@#Description #@#
Stop allowing uncontrolled air and contaminants to compromise cleanliness at entry points. This low-profile air curtain delivers targeted, continuous airflow to protect interior zones, maintain sanitation, and minimize infiltration across doorways up to 7 feet high. Engineers designed the unit for both interior and exterior mounting, featuring a single 1.5 horsepower motor and a 120 volts 1-Ph electrical configuration to seamlessly integrate with existing facility systems.
#@@# Motor Power#@#
The unit utilizes one 1.5 HP motor to generate a stable air stream that effectively minimizes dust and airborne particles crossing thresholds. Facility teams can achieve consistent performance with a single-speed motor, simplifying operation and reducing potential points of failure.
#@@# Mounting Flexibility#@#
Engineers configured the cabinet for both interior and exterior mounting to accommodate various installation scenarios in kitchens, hospitals, schools, and bars. Technicians can install the low-profile housing above openings where space constraints exist, ensuring robust protection without compromise.
#@@# Door Coverage#@#
Manufactured for openings up to 7 feet, the curtain provides ample width and throw to cover standard commercial entry heights. Maintenance staff can expect uniform airflow across the span, thanks to a model width of 48.06 inches and precise motor output.
#@@# Electrical Compliance#@#
The device operates on 120 volts at 60 hertz in a single-phase arrangement and carries UL and cULus approvals, along with UL EPH listing. Safety officers appreciate the documented certifications that align with commercial electrical codes.
#@@# Construction Profile#@#
Built with an 8.5-inch height profile and a total unit weight of approximately 54 pounds, the assembly fits compact soffits and low mounting zones while remaining serviceable. Operations managers note that the low profile reduces visual impact in hospitality and institutional environments.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the air curtain weekly and remove dust from the intake grille to maintain airflow and heat transfer. Use a soft brush and low-pressure vacuum for the motor housing and fan blades; avoid solvents that harm bearings. Tighten mounting hardware monthly and check that the unit is level for a consistent discharge pattern. Test electrical connections quarterly and confirm 120v, 1-Ph supply continuity before service. Replace worn seals on adjacent doors to reduce infiltration.