Skip to main content

Berner PT06-C-1060E 60" L White Powder Coat Electric Heated Pass-Thru Unit 6 Series - 208 Volts

Berner

$2,119.00
(No reviews yet) Write a Review
SKU:
PT06-C-1060E
Weight:
86.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
PT06-C-1060E__6015
Exterior Finish:
White Powder Coat
Width (side - side):
60" - 71"
Tags:
Air Curtain
Label Option type:
rectangles
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
Packed By:
1 Each
Manufacturer:
Berner
Trigger BC Integration:
Y-1/12/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
86
cULus Certified:
Yes
Phase:
1-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Voltage:
208 Volts
Filter_Horsepower:
1/5 HP
Primary Image:
Berner_PT06-C-1060E.PNG
specsheet:
Berner_PT06-C-1060E.pdf
email_price:
no
Net Price:
1630.00
msrp_price:
no
call_price:
no
map_price:
yes
add_to_cart:
no
MAP Price:
2119.00
login_price:
no
List Price:
3260
Sale Price:
2119.00
Filter_Made in America:
Yes
Voltage:
208v
Filter_Width:
60 - 84 Inches
is free shipping:
Yes
Keyfeatures5:
cULus certified, made in the USA
Keyfeatures4:
208 volts, 1-Ph for commercial sites
Keyfeatures6:
60" nominal length
Keyfeatures:
Electric heated pass-thru for openings up to 6' high
Keyfeatures3:
Single 1/5 HP variable-speed motor for airflow
Keyfeatures2:
White powder coat exterior for corrosion resistance
short_description:
Berner PT06-C-1060E heated pass-thru unit offers electric heat with a 1/5 HP motor and 60" length for openings up to 6 feet.
Adding to cart… The item has been added
Stop compromising climate control at doorways. This electric heated pass-thru unit delivers controlled airflow and consistent heat output to protect interior environments, reduce energy loss, and maintain sanitation standards in high-traffic facilities. Designed for commercial installations, it supports openings up to 6 feet and integrates with interior or exterior mounting configurations for flexible placement.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior surfaces and intake grille daily with a microfiber cloth and mild detergent; avoid abrasives. Sanitize high-touch zones (controls, handles, mounting edges) with EPA-registered surface disinfectant per label dwell time. Inspect motor intake and clean filter every 30 days; remove debris while unit is off and locked out. Regular cleaning prevents cross-contamination, supports health-code compliance, deters pests, and preserves finish and function.#@@#Additional Info#@#Berner PT06-C-1060E heated air curtain, 60" L, provides electric heat at 208 volts with a 1/5 HP motor. It mounts for openings up to 6 Ft., has a white powder coat finish, is cULus certified, made in the USA, and is ideal for commercial foodservice.#@@#General Info#@#Description #@# Stop compromising climate control at doorways. This electric heated pass-thru unit delivers controlled airflow and consistent heat output to protect interior environments, reduce energy loss, and maintain sanitation standards in high-traffic facilities. Designed for commercial installations, it supports openings up to 6 feet and integrates with interior or exterior mounting configurations for flexible placement. #@@# Motorized Airflow#@# A variable speed 1/5 HP motor drives a single fan to produce a steady curtain of conditioned air across openings. Installers gain precise control over airflow rates to match traffic patterns and minimize infiltration in corridors, kitchens, and loading zones. #@@# Electric Heat Delivery#@# Integrated electric heating elements provide reliable warm air to counteract cold drafts and temperature gradients near doorways. Facilities achieve rapid temperature stabilization without introducing combustion byproducts, supporting indoor air quality and occupant comfort. #@@# Application Flexibility#@# Configure the unit for interior or exterior mounting to suit doorway orientation and architectural constraints. Technicians select mounting locations based on airflow trajectories and clearance requirements, enabling consistent performance for openings up to 6 feet high. #@@# Durable Exterior Finish#@# A white powder coat exterior resists corrosion and simplifies cleaning in demanding service environments. Maintenance crews find the smooth finish easy to wipe down and compatible with standard sanitation procedures used in food service, healthcare, and institutional settings. #@@# Electrical Compatibility#@# Engineered for 208 volts single phase at 60 hertz, the unit aligns with common commercial electrical infrastructures. Electrical installers appreciate the straightforward connection requirements and the cULus certification that documents compliance with safety standards. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the Berner PT06-C-1060E electrical connections monthly and tighten terminal screws to maintain 208 volts continuity. Clean intake grilles and heater elements weekly with compressed air and a soft brush to prevent dust buildup. Lubricate the 1/5 HP motor bearings quarterly per manufacturer guidance and verify motor mounting for vibration. Test airflow across 6 Ft. openings after each service and replace damaged seals immediately to sustain performance.