Skip to main content

Berner IDC14-1060E 60" W Electric Heated 1 Motor Interior Mounting Industrial Series Direct Drive Air Curtain - 208 Volts 3-Ph

Berner

$3,092.70
(No reviews yet) Write a Review
SKU:
IDC14-1060E
Weight:
181.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
IDC14-1060E__6015
Width (side - side):
60" - 71"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
2379.00
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
3092.70
Manufacturer:
Berner
login_price:
no
List Price:
4758
Trigger BC Integration:
Y-1/13/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
181
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Voltage:
208 Volts
Filter_Features:
Electric Heater
Filter_Width:
60 - 84 Inches
Filter_Horsepower:
1 HP
Primary Image:
Berner_IDC14-1060E.png
specsheet:
Berner_IDC14-1060E.pdf
warranty:
Berner_IDC14-1060E_1.pdf
manual:
Berner_IDC14-1060E_2.pdf
Sale Price:
3092.70
Voltage:
208v
Filter_Speeds:
1-Speed
is free shipping:
Yes
Keyfeatures5:
cULus certified, MADE IN USA
Keyfeatures4:
Interior mounting with inlet protection screen
Keyfeatures6:
Compatible with 208 volts, 3-Ph power
Keyfeatures:
Electric 14 kW heating for thermal separation
Keyfeatures3:
For doors up to 14 feet high
Keyfeatures2:
1 HP direct-drive motor for continuous duty
short_description:
Built for commercial use, the Berner IDC14-1060E air curtain provides thermal separation with electric heat and a 1 HP motor for interior mounting.
Adding to cart… The item has been added
Stop compromising environmental control for convenience. This electric heated industrial air curtain delivers consistent separation between conditioned interiors and challenging exteriors while maintaining throughput at high-traffic openings. Designed for interior mounting, this system combines targeted airflow and electric heat to reduce infiltration, protect indoor climate, and minimize insect entry for doors up to 14 feet high.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe external housing and inlet screen daily with a soft cloth and neutral detergent; rinse and dry. Sanitize high-touch zones like pull switches and access panels with an EPA-registered disinfectant per label contact time. Inspect fasteners and motor access weekly; tighten and clear debris to prevent contamination and pests. Record cleaning and sanitizer concentrations in CSA-aligned logs to support inspections and preserve equipment life.#@@#Additional Info#@#Berner’s IDC14-1060E air curtain offers 60" coverage with a 1 HP motor, 208 volts 3-Ph operation, and 14 kW heat output. It protects separation to 14 ft, insect control to 12 ft, includes an inlet screen, cUlus certification, and is MADE IN USA.#@@#General Info#@#Description #@# Stop compromising environmental control for convenience. This electric heated industrial air curtain delivers consistent separation between conditioned interiors and challenging exteriors while maintaining throughput at high-traffic openings. Designed for interior mounting, this system combines targeted airflow and electric heat to reduce infiltration, protect indoor climate, and minimize insect entry for doors up to 14 feet high. #@@# Airflow Performance#@# Engineered with a direct drive motor, this unit produces a focused air stream that creates a reliable barrier across a 60-inch opening. Units accommodate openings to 14 feet for environmental separation and to 12 feet for insect protection, allowing facility managers to maintain interior conditions in high-traffic applications. #@@# Electric Heat Output#@# Equipped with 14kW electric heat, the curtain supplies consistent thermal reinforcement to the air stream, reducing cold drafts and stabilizing indoor temperatures near doorways. Technicians will appreciate predictable heat capacity when integrating with existing heating systems. #@@# Motor and Drive#@# A single 1 HP motor provides robust, continuous operation on a direct drive platform, minimizing mechanical complexity and maintenance time. Operators benefit from simplified service procedures and durable motor design in high-duty cycle locations. #@@# Electrical Configuration#@# Designed for 208 volts, 3-phase power, the unit integrates with standard commercial electrical infrastructure and supports 60 hertz operation. Facilities that follow commercial electrical standards gain straightforward installation and reliable compatibility. #@@# Construction and Certification#@# Built in the USA, this construction combines heavy gauge components with an inlet screen to protect internal elements and extend service life under commercial use conditions. CSA and cULus certification confirm compliance with applicable safety standards for institutional installations. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the IDC14-1060E air curtain monthly and remove debris from the inlet screen to maintain designed airflow. Tighten mounting hardware and verify electrical connections at 208 volts, 3-Ph, and confirm motor rollers rotate freely. Replace worn seals to preserve environmental separation for openings up to 14 feet. Clean heated elements with a soft brush after power isolation. Log maintenance actions and measure current draw to detect motor anomalies.