Skip to main content

Berner IDC12-1060E 60" W Heated Industrial Series Direct Drive Air Curtain - 208 Volts 3-Ph

Berner

$2,585.05
(No reviews yet) Write a Review
SKU:
IDC12-1060E
Weight:
178.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
IDC12-1060E__6015
Width (side - side):
60" - 71"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
1988.50
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
2585.05
Manufacturer:
Berner
login_price:
no
List Price:
3977
Trigger BC Integration:
Y-1/13/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
178
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Voltage:
208 Volts
Filter_Width:
60 - 84 Inches
Filter_Horsepower:
1/2 HP
Primary Image:
Berner_IDC12-1060E.png
specsheet:
Berner_IDC12-1060E.pdf
warranty:
Berner_IDC12-1060E_1.pdf
manual:
Berner_IDC12-1060E_2.pdf
Sale Price:
2585.05
Filter_Made in America:
Yes
Voltage:
208v
Filter_Speeds:
1-Speed
is free shipping:
Yes
Keyfeatures5:
cULus certified, MADE IN USA
Keyfeatures4:
14 kW electric heat for separation
Keyfeatures6:
Interior mounting with inlet screen for maintenance
Keyfeatures:
60" heated air curtain for 12 Ft openings
Keyfeatures3:
1/2 HP motor for continuous operation
Keyfeatures2:
208 volts, 3-Ph compatibility
short_description:
Designed for heavy-duty entrances, the Berner IDC12-1060E heated air curtain offers environmental separation for doors up to 12 feet and insect protection for doors up to 10 feet.
Adding to cart… The item has been added
Stop sacrificing climate control for convenience. This heated industrial air curtain provides targeted thermal separation and reliable insect control while operating on 208 volts 3-Ph power. This allows facilities to maintain internal temperatures and reduce HVAC load simultaneously. Installers and facility managers will appreciate the straightforward mounting options and robust construction designed for commercial duty.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe air curtain surfaces and inlet screen daily with a microfiber cloth and mild detergent; rinse and dry. Sanitize high-touch zones like door frames and switches with an EPA-approved disinfectant. Inspect the motor area weekly; clear debris and tighten fasteners. Follow manufacturer service intervals for heated elements and electrical checks. Regular cleaning prevents contamination, maintains inspection readiness, deters pests, and preserves function.#@@#Additional Info#@#Berner IDC12-1060E 60" heated air curtain delivers 14 kW heat and a 1/2 HP motor for doors up to 12 Ft.; operates on 208 volts, 3-Ph, includes inlet screen, interior mounting, cULus certification, and is made in USA.#@@#General Info#@#Description #@# Stop sacrificing climate control for convenience. This heated industrial air curtain provides targeted thermal separation and reliable insect control while operating on 208 volts 3-Ph power. This allows facilities to maintain internal temperatures and reduce HVAC load simultaneously. Installers and facility managers will appreciate the straightforward mounting options and robust construction designed for commercial duty. #@@# Motor Driven Flow#@# A 1/2 HP direct drive motor produces consistent airflow tailored for doorways up to 12 feet high for environmental separation and up to 10 feet high for insect protection. Technicians benefit from a single motor design that simplifies maintenance and reduces parts inventory. #@@# Electric Heat Output#@# A 14kW electric heating element ensures rapid temperature recovery across the opening, minimizing the infiltration of cold air during frequent door cycles. Operators will notice improved interior climate stability that supports comfort and process control. #@@# Single Speed Control#@# A one-speed control delivers predictable performance and straightforward operation for staff who require simple, repeatable settings. Maintenance teams experience fewer failure modes and faster troubleshooting with uncomplicated controls. #@@# Heavy Duty Housing#@# A rigid housing specified for interior mounting resists deformation in high-traffic environments and supports long service life under continuous operation. Facility managers will gain dependable operation that aligns with scheduled preventive maintenance intervals. #@@# Safety and Certification#@# cULus certification verifies compliance with recognized safety standards and streamlines approval in regulated facilities such as hospitals, schools, and commercial kitchens. Procurement teams can document conformity during audits and installations. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the IDC12-1060E air curtain monthly and clean the inlet screen to maintain airflow. Remove dust from the blower and motor housing with compressed air; avoid water contact with electrical components. Verify mounting hardware and sealant; tighten fasteners and reseal gaps to preserve thermal separation. Test electric heat at 208v 3-Ph connections and confirm 1/2 HP motor operates at rated speed. Calibrate clearance for doors up to 12 feet to ensure effective environmental control.