Skip to main content

Berner ARD12-2108E Heated Architectural Series Recessed 12 Air Door - 208 Volts 1-Ph

Berner

$4,942.60
(No reviews yet) Write a Review
SKU:
ARD12-2108E
Weight:
293.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
ARD12-2108E__6015
Width (side - side):
108" - 119"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
3802.00
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
4942.60
Manufacturer:
Berner
login_price:
no
List Price:
7604
Trigger BC Integration:
Y-1/6/2026_6:15PM
Made in USA:
Yes
Taxonomy Weight:
293
cULus Certified:
Yes
Phase:
1-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Speeds:
10-Speeds
Filter_Voltage:
208 Volts
Filter_Horsepower:
1/2 HP
Primary Image:
Berner_ARD12-2108E.png
specsheet:
Berner_ARD12-2108E.pdf
warranty:
Berner_ARD12-2108E_1.pdf
manual:
Berner_ARD12-2108E_2.pdf
Sale Price:
4942.60
Filter_Made in America:
Yes
Voltage:
208v
Filter_Width:
85 - 109 Inches
is free shipping:
Yes
Keyfeatures5:
Mounting for heights up to 12 Ft
Keyfeatures4:
Ten-speed control for precise performance
Keyfeatures6:
cULus certified, MADE IN USA
Keyfeatures:
Electric heated recessed air curtain
Keyfeatures3:
Two 1/2 HP motors for reliable airflow
Keyfeatures2:
108"–119" width fits standard openings
short_description:
Engineers designed the berner ARD12-2108E heated air door for high-traffic openings, providing heated airflow with two 1/2 HP motors and ten-speed control for heights up to 12 feet.
Adding to cart… The item has been added
Stop compromising door performance for climate control. This heated recessed air door delivers consistent thermal separation and reliable airflow for high-traffic openings, maintaining conditioned zones while reducing infiltration. Designed for commercial installations, this unit provides electric heat, dual motors, and adjustable speed to match throughput and mounting requirements.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior surfaces and high-touch zones (menu holders, shakers, chair backs, door handles) with EPA-registered disinfectant; follow dwell time on label. Remove debris from under shelves and booth crevices to deter pests. Clean metal rails and panels with nonabrasive cleaner to prevent corrosion. Inspect fasteners monthly and tighten. Regular cleaning prevents germ transfer, shapes customer perception, ensures visible compliance with health inspectors, and preserves furnishings.#@@#Additional Info#@#Berner ARD12-2108E Heated Architectural Series air door offers 108" coverage with two 1/2 HP motors, ten-speed control, and 28 kW electric heat at 208 volts. cULus certified, made in USA, for mounting heights up to 12 ft, weighing 293 pounds.#@@#General Info#@#Description #@# Stop compromising door performance for climate control. This heated recessed air door delivers consistent thermal separation and reliable airflow for high-traffic openings, maintaining conditioned zones while reducing infiltration. Designed for commercial installations, this unit provides electric heat, dual motors, and adjustable speed to match throughput and mounting requirements. #@@# Heated Air Curtain#@# Electric heating supplies 28kW of thermal output to counteract cold drafts and reduce load on HVAC systems. Engineers designed the heater for mounting heights up to 12 feet, enabling uniform air barrier performance for tall openings. #@@# Dual Motor Design#@# Two 1/2 HP motors deliver robust airflow and redundancy for continuous operation. Facility managers gain operational flexibility and reduced downtime through independent motor operation. #@@# Variable Speed Control#@# Ten speeds allow technicians to tune airflow to specific door widths and traffic patterns. Operators achieve optimal air separation and energy efficiency by matching speed to environmental conditions. #@@# Recessed Installation#@# Recessed architectural design integrates into door surrounds to preserve sight lines and building aesthetics. Installers find the hinged white aluminum bottom access panel simplifies service and maintenance access. #@@# Industrial Voltage#@# Engineered for 208 volts single-phase power, the unit connects to common commercial electrical infrastructure. Electric specification supports high thermal output while meeting standard site electrical capacity. #@@# Compliance and Origin#@# cULus certification validates safety and regulatory compliance for North American installations. Manufacturing in the USA ensures traceable components and accessible support for service networks. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the ARD12-2108E air door monthly for loose fasteners and secure all mounting points to prevent vibration. Clean intake grilles and blower wheels with a vacuum and soft brush to maintain airflow. Replace worn seals and check the access panel operation for serviceability. Lubricate motor bearings per manufacturer intervals and verify motor current draw matches ratings. Test the ten-speed controller and thermostat for correct cycling.