Skip to main content

Berner ARC16-4144E-3 144" W Heated Architectural Series Recessed 16 Air Door - 480 Volts 3-Ph

Berner

$11,049.35
(No reviews yet) Write a Review
SKU:
ARC16-4144E-3
Weight:
485.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
ARC16-4144E-3__6015
Width (side - side):
144" - 155"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
8499.50
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
11049.35
Manufacturer:
Berner
login_price:
no
List Price:
16999
Trigger BC Integration:
Y-1/14/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
485
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Speeds:
2-Speeds
Filter_Voltage:
480 Volts
Filter_Width:
130 - 159 Inches
Filter_Horsepower:
1 HP
Primary Image:
Berner_ARC16-4144E-3.png
specsheet:
Berner_ARC16-4144E-3.pdf
warranty:
Berner_ARC16-4144E-3_1.pdf
manual:
Berner_ARC16-4144E-3_2.pdf
Sale Price:
11049.35
Filter_Made in America:
Yes
Voltage:
480v
is free shipping:
Yes
Keyfeatures5:
Mounts for openings up to 16 feet
Keyfeatures4:
Intelliswitch controller for precise operation
Keyfeatures6:
cULus certified, made in USA
Keyfeatures:
144" recessed heated air curtain
Keyfeatures3:
Four 1 HP motors, two-speed control
Keyfeatures2:
480 volts 3-Ph high-voltage power
short_description:
Engineered for heavy-duty entrances, the Berner ARC16-4144E-3 144" heated air door delivers 16 air streams with four 1 HP motors and two-speed operation.
Adding to cart… The item has been added
Stop sacrificing entry integrity for convenience. This recessed heated air door delivers targeted thermal separation and high airflow to maintain climate control at large openings while minimizing conditioned air loss and infiltration. Designed for mounting in expansive commercial spaces, this unit provides robust thermal delivery and reliable operation for facilities that require continuous performance.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe exterior surfaces with a mild detergent and soft cloth; rinse and dry. Sanitize high-touch zones (menu covers, chair backs, handles, shakers) with EPA-registered disinfectant per label contact time. Vacuum or brush crevices under booths and shelving to remove crumbs. Inspect and remove spills immediately to prevent staining and pest attraction. Clean weekly to maintain appearance, pass inspections, and prevent cross-contamination between front- and back-of-house.#@@#Additional Info#@#Berner ARC16-4144E-3 144" heated recessed air door delivers 16 air streams with four 1 HP motors, two speeds, and Intelliswitch control for mounting up to 16 ft; 480 volts, 3-Ph, 56 kW electric heating, cULus certified, 485 pounds, made in USA.#@@#General Info#@#Description #@# Stop sacrificing entry integrity for convenience. This recessed heated air door delivers targeted thermal separation and high airflow to maintain climate control at large openings while minimizing conditioned air loss and infiltration. Designed for mounting in expansive commercial spaces, this unit provides robust thermal delivery and reliable operation for facilities that require continuous performance. #@@# Four Motors#@# Four 1 HP motors drive the air curtain, producing concentrated airflow across the entire 144" span to block drafts and reduce infiltration. Engineers specified multiple motors to ensure balanced pressure distribution and to allow a single motor to run while others remain available for redundancy. #@@# Two Speed Control#@# A two-speed motor arrangement provides operational flexibility for varying traffic and load conditions, allowing operators to switch between energy-conserving low flow and higher flow for peak times. Facility teams gain control over airflow and noise levels while matching performance to occupancy. #@@# Electric Heating#@# The unit incorporates electric heat rated at 56 kW to deliver consistent thermal output across the opening, reducing heat loss and improving occupant comfort near the threshold. Technicians can rely on a high-voltage heating package that integrates with three-phase power for stable thermal delivery. #@@# Intelliswitch Controller#@# An Intelliswitch controller provides simplified system control and coordinated operation of motors and heating elements, facilitating consistent startup and safe shutdown sequences. Maintenance staff receive clear control logic that reduces troubleshooting time and supports predictable responses to input changes. #@@# Recessed Mounting#@# Recessed architectural mounting fits into overhead cavities for a discreet installation that preserves facility sight lines while protecting components from tampering. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect intake grilles weekly and remove debris to maintain airflow and heating efficiency. Schedule quarterly lubrication of four motors and verify two-speed operation via the Intelliswitch controller. Test electrical connections and tighten terminals on 480 volts 3-Ph circuits during each maintenance visit. Replace worn seals and check the hinged bottom access panel for corrosion; clean with nonabrasive detergent. Record service actions with date and technician name to ensure CSA compliance.