Skip to main content

Berner ARC16-3120E-2-3 120" W Heated Architectural Series Recessed 16 Air Door - 208 Volts 3-Ph

Berner

$8,075.60
(No reviews yet) Write a Review
SKU:
ARC16-3120E-2-3
Weight:
367.00 LBS
Shipping:
Calculated at Checkout
SKU Number:
ARC16-3120E-2-3__6015
Width (side - side):
120" - 131"
email_price:
no
Tags:
Air Curtain
Label Option type:
rectangles
Net Price:
6212.00
msrp_price:
no
Ship From:
16101
Product Taxonomy:
CulinaryDepot>>Janitorial Supply>>Facility Maintenance and Sanitation>>Air Curtains
call_price:
no
map_price:
yes
Mfr Toll Free:
(800) 343-7991
Freight Class:
85
Packed By:
1 Each
add_to_cart:
no
MAP Price:
8075.60
Manufacturer:
Berner
login_price:
no
List Price:
12424
Trigger BC Integration:
Y-1/13/2026_6:00PM
Made in USA:
Yes
Taxonomy Weight:
367
cULus Certified:
Yes
Phase:
3-Ph
Hertz:
60
Filter_Manufacturer:
Berner
Filter_Speeds:
2-Speeds
Filter_Voltage:
208 Volts
Filter_Width:
110 - 129 Inches
Filter_Horsepower:
1 HP
Primary Image:
Berner_ARC16-3120E-2-3.png
specsheet:
Berner_ARC16-3120E-2-3.pdf
warranty:
Berner_ARC16-3120E-2-3_1.pdf
manual:
Berner_ARC16-3120E-2-3_2.pdf
Sale Price:
8075.60
Filter_Made in America:
Yes
Voltage:
208v
is free shipping:
Yes
Keyfeatures5:
cULus certified, MADE IN USA
Keyfeatures4:
208 volts, 3-Ph, 42 kW power
Keyfeatures6:
Hinged white aluminum access panel
Keyfeatures:
120" heated air door for 16' openings
Keyfeatures3:
Intelliswitch controller for operation
Keyfeatures2:
Three 1 HP motors with two-speed control
short_description:
Built for heavy-duty entrances, the Berner ARC16-3120E-2-3 heated air door creates a controlled barrier across 120" widths with three 1 HP motors.
Adding to cart… The item has been added
Stop sacrificing entry efficiency for climate control. This heated recessed air door delivers continuous high-volume air separation while reducing infiltration and maintaining conditioned interior environments in busy facilities. Built for installation across wide openings, the unit combines robust heating capacity with specified motor control to sustain performance at mounting heights up to 16 feet.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch surfaces (menu covers, shakers, chair backs, door handles) with EPA-approved disinfectant; allow dwell time per label. Clean tables, shelving, and booth crevices daily to remove crumbs and grease. Spot-clean spills immediately; vacuum or sweep under shelves and booths weekly. Sanitize non-food-contact areas before service to reduce Norovirus transfer, deter pests, maintain inspections, and preserve furniture lifespan.#@@#Additional Info#@#Berner ARC16-3120E-2-3 is a 120" recessed heated air door with three 1 HP motors, two-speed control, and Intelliswitch controller; it delivers 42 kW at 208 volts, 3-Ph for openings up to 16' and is cULus certified, made in USA.#@@#General Info#@#Description #@# Stop sacrificing entry efficiency for climate control. This heated recessed air door delivers continuous high-volume air separation while reducing infiltration and maintaining conditioned interior environments in busy facilities. Built for installation across wide openings, the unit combines robust heating capacity with specified motor control to sustain performance at mounting heights up to 16 feet. #@@# Three Phase Power#@# The unit operates on 208 volts three-phase power and uses 42kW electric heating to produce consistent thermal output for wide openings. Operators will limit cold air intrusion even during peak traffic because the design provides sustained heated airflow across the full 120-inch width. #@@# Multi Motor Design#@# Three 1 HP motors drive the air curtain to generate uniform airflow across the opening. Facility teams will achieve stable performance and redundancy since multiple motors distribute load and maintain function if one motor requires service. #@@# Two Speed Control#@# An integrated two-speed motor arrangement provides selectable flow rates to match traffic patterns and load variations. Maintenance staff will conserve energy and adapt airflow intensity quickly when conditions change, using fewer runtime hours at high speed when not required. #@@# Intelliswitch Controller#@# The Intelliswitch controller delivers straightforward operational control and sequencing for heater and fan functions. Technicians will benefit from simplified commissioning and predictable control logic that reduces troubleshooting time on site. #@@# Hinged Access Panel#@# A hinged white aluminum bottom access panel allows safe front access to internal components without removing the unit from the recess. Service crews will perform inspections and routine maintenance faster, minimizing downtime and labor costs during scheduled servicing. #@@#Delivery Details#@# • Please ensure to handle the product with utmost care. • Check if the product you have received has all the essential parts and accessories. • Make sure to examine the product for damage before signing the delivery receipt. • Contact customer service for delivery concerns. • Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Service personnel should inspect the Berner ARC16-3120E-2-3 air door monthly for secure mounting, fan alignment, and wear. Clean intake and discharge grilles with compressed air or a soft brush. Lubricate motor bearings as per manufacturer intervals and check electrical connections at 208 volts and three-phase terminals. Replace filters and verify the Intelliswitch controller function; test both speeds and heater elements. Document all actions for CSA compliance and inventory control.