Stop allowing drafts of conditioned air to compromise entrance comfort and energy performance. This air curtain delivers targeted airflow for doors up to 10 feet high, combining dual motor power with precise three-speed control to maintain separation between indoor climate and outdoor conditions. Designed for professional installations, the unit mounts on a wall plate and operates on standard 120 volts, 1-Ph power for straightforward integration into existing electrical systems.
LongDescription#@#NA#@@#Cleaning Instructions#@#Wipe high-touch zones (menu covers, shakers, chair backs, door handles) with EPA-approved disinfectant; use microfiber and follow dwell time. Clean under booths and shelves daily to remove crumbs and prevent pests. Rinse non-porous surfaces after cleaning when required. Inspect and tighten fittings weekly. Regular cleaning prevents germ transfer to food and staff, maintains customer perception, and helps meet visible health-code expectations.#@@#Additional Info#@#Berner AHC10-2048A is a 48" un-heated air curtain with two 1/2 HP motors, three speeds, and 120v 1-Ph power for 10 Ft. openings; anodized aluminum housing, wall-mount plate, .71 kW draw, cULus certified, made in USA, 122 pounds.#@@#General Info#@#Description #@#
Stop allowing drafts of conditioned air to compromise entrance comfort and energy performance. This air curtain delivers targeted airflow for doors up to 10 feet high, combining dual motor power with precise three-speed control to maintain separation between indoor climate and outdoor conditions. Designed for professional installations, the unit mounts on a wall plate and operates on standard 120 volts, 1-Ph power for straightforward integration into existing electrical systems.
#@@# Motor Configuration#@#
Two 1/2 HP motors provide sustained airflow and redundancy, supporting continuous operation in high-traffic settings. Engineers will appreciate the balanced load distribution that reduces strain and extends service intervals.
#@@# Speed Control#@#
Three speed settings enable technicians to adjust output for varying wind loads and traffic patterns, delivering consistent air shear as conditions change throughout the day. Operators can lower fan speed to reduce noise during light use and increase it during peak entry periods.
#@@# Coverage Capacity#@#
The unit effectively covers openings up to 10 feet high, ensuring separation for typical commercial doors in restaurants, hospitals, and educational facilities. Installers can expect uniform flow across the 48-inch length to minimize infiltration and maintain interior setpoints.
#@@# Construction Materials#@#
Anodized aluminum housing resists corrosion in demanding environments while keeping overall weight manageable at approximately 122 pounds. Facilities managers receive a durable casing that simplifies cleaning and supports a long service life.
#@@# Energy Performance#@#
The unheated design consumes 0.71 kW, reducing electrical demand compared with heated alternatives and offering efficient continuous operation on 120 volts. Procurement teams will recognize savings potential through lower operating costs and simplified electrical requirements.
#@@#Delivery Details#@#
• Please ensure to handle the product with utmost care.
• Check if the product you have received has all the essential parts and accessories.
• Make sure to examine the product for damage before signing the delivery receipt.
• Contact customer service for delivery concerns.
• Delivery times may vary based on location.#@@#deliverynotes#@#NA#@@#Maintenance Guide#@#Inspect the unit monthly and remove dust from the intake and outlet grilles using a soft brush or vacuum with a brush attachment. Tighten mounting fasteners and verify the wall plate remains level. Lubricate motor bearings per manufacturer intervals and replace worn belts or hardware immediately. Test electrical connections at 120v and confirm both 1/2 HP motors operate across three speeds. Record service dates and note cULus compliance for inspections.